AS-Interface

AS-Interface Safety at work

AS-Interface position switches

Selection and Ordering data (continued)

 

Design

 

 

 

Order No.

 

 

AS-Interface position switch, with separate actuator

 

 

 

 

With direct connection of AS-Interface to Safety at Work

 

 

 

 

For use up to Category 2 acc. to EN 954-1

 

 

 

 

 

 

 

IP65, Slow-action contact, 2 NC

 

 

 

 

 

 

 

Molded plastic enclosure, side operation, fixing acc. to EN 50 047

 

 

 

 

 

 

 

 

3SF3 200-6XX03-0BA1

 

 

 

 

 

 

 

Molded plastic enclosure, front operation, fixing acc. to EN 50 047

 

 

 

 

 

 

 

 

3SF3 200-6XX04-0BA1

 

 

 

 

 

 

 

Molded plastic enclosure, side and front operation, 52 mm wide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 30 N extraction force

 

 

 

 

 

 

 

 

 

 

3SF3 243-0XX00-0BA1

 

 

 

 

 

 

 

 

 

- 5 N extraction force

 

 

 

 

 

 

 

 

 

 

3SF3 243-0XX40-0BA1

 

 

 

 

 

 

 

 

 

- Automatic ejection

 

 

 

 

 

 

 

 

 

 

3SF3 243-0XX30-0BA1

 

 

 

 

 

 

 

 

 

Metal enclosure, fixing acc. to EN 50 041

 

 

 

 

 

 

 

 

 

 

3SF3 120-6XX00-0BA1

 

 

 

 

 

 

 

 

 

Actuator

 

 

 

 

 

 

 

• Standard, Width/length of enclosure

79 mm

 

 

 

 

 

 

 

 

3SX3 197

 

 

 

 

 

 

 

• With crosswise fixing, Width/length of enclosure

50 mm

 

 

 

 

 

 

 

 

3SX3 206

 

 

 

 

 

 

 

• Universal radius, Width/length of enclosure

80 mm

 

 

 

 

 

 

 

 

3SX3 203

 

 

 

 

 

 

 

AS-Interface position switch with separate actuator and M12 connector

 

 

 

 

M12 connector for connecting an additional position switch

 

 

 

 

Direct connection of AS-Interface to Safety at Work

 

 

 

 

 

 

 

For use up to Category 4 acc. to EN 954-1

 

 

 

 

 

 

 

IP65, Slow-action contact, one NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Molded plastic enclosure

 

 

 

 

 

 

 

Side and front operation

 

 

 

 

 

6

 

52 mm wide

 

 

 

 

 

 

• 30 N extraction force

 

 

 

 

 

 

 

 

 

3SF3 257-6XX00-0BA2

 

 

 

 

 

 

 

• 5 N extraction force

 

 

 

 

 

 

3SF3 257-6XX00-0BA2

 

 

 

3SF3 257-6XX40-0BA2

 

 

 

 

 

 

 

 

• Automatic ejection

 

 

 

 

 

 

 

 

 

 

3SF3 257-6XX30-0BA2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Actuator

 

 

 

 

 

 

 

• Standard, Width/length of enclosure

27 mm

 

 

 

 

 

 

 

 

3SX3 218

 

 

 

 

 

 

 

(rmin = 150 mm)

 

 

 

 

 

 

 

• Universal radius, Width/length of enclosure

33 mm

 

 

3SX3 228

 

 

 

 

 

 

 

(rmin = 45 mm)

 

 

 

 

 

 

3SF3 750-6XX00-0BA1

3SF3 830-6XX00-0BA1

AS-Interface position switch, with separate actuator and tumbler

With direct connection of AS-Interface to Safety at Work

For use up to Category 4 acc. to EN 954-1

IP65, Pg 13.5, Solenoid voltage 24 V DC

Monitoring of actuator and solenoid position

Plastic housing

- Locking force 1200 N, locked by spring force

 

3SF3 760-6XX00-0BA1

- Locking force 1200 N, locked by magnetic force

3SF3 750-6XX00-0BA1

Actuator

 

 

• Standard,

 

3SX3 252

• with crosswise fixing

 

3SX3 253

• radius

 

3SX3 254

Metal housing

 

 

- Locking force 1200 N, locked by spring force

 

3SF3 860-6XX00-0BA1

- Locking force 1200 N, locked by magnetic force

3SF3 850-6XX00-0BA1

- Locking force 2000 N, locked by spring force

 

3SF3 840-6XX00-0BA1

- Locking force 2000 N, locked by magnetic force

3SF3 830-6XX00-0BA1

Actuator

 

 

• Standard, length

79 mm

3SX3 197

- for left approach direction, length

132 mm

3SX3 207

- with crosswise fixing, length

50 mm

3SX3 206

• Universal radius, length

80 mm

3SX3 203

Forced opening IEC 60 947-5-1, Appendix K.

1)1) Accessories, technical data, contact travel, circuit diagrams and dimensional drawings for the specified basic switch can be found in the Catalog LV 10, Edition 2004, Section AS-Interface Safety Systems.

Siemens IK PI · 2004

6/17

Page 17
Image 17
Siemens EN 50295 3SF3 200-6XX03-0BA1, 3SF3 200-6XX04-0BA1, 3SF3 243-0XX00-0BA1, 3SF3 243-0XX40-0BA1, 3SF3 243-0XX30-0BA1

EN 50295 specifications

Siemens EN 50295 is emerging as a pivotal standard in the domain of electrical safety and design, particularly relevant for the electrical industry and equipment manufacturing sectors. Primarily, this European Norm is geared towards ensuring the safety of electrical systems used in dry environments, which is essential for various industrial applications.

One of the main features of the EN 50295 standard is its comprehensive safety requirements which are aimed at mitigating the risks associated with electrical systems. This includes aspects like insulation resistance, protective earthing, and the management of electrical faults. By setting a benchmark for safety, Siemens EN 50295 assists manufacturers in maintaining compliance with national and international regulations, thus protecting both users and equipment.

The standard emphasizes the importance of safety measures in the design process. It outlines criteria for components, assembly methods, and system installation, ensuring that electrical equipment operates stably and gets rid of risks related to electrical failures. This involves rigorous testing of materials and components, which enhances their reliability and longevity while providing efficient overall operation.

Siemens EN 50295 also incorporates advancements in technology, acknowledging the significance of intellectual innovation in the industry. It encourages the integration of smart technologies and automation features into electrical systems, paving the way for enhanced operational efficiencies. Such technologies not only improve the performance of electric systems but also contribute to energy conservation, reducing the overall environmental footprint.

Another characteristic of the EN 50295 standard is its adaptability. The framework it provides can be customized depending on specific industry needs, making it versatile across various sectors such as manufacturing, construction, and transportation. This adaptability ensures that businesses can maintain high safety standards while still allowing room for innovation and modern practices.

In summary, Siemens EN 50295 presents a well-rounded approach to enhancing safety, reliability, and sustainability in electrical systems. Its features and characteristics are set to guide industries in making informed decisions regarding electrical configuration, ultimately fostering a safer and more efficient working environment. The incorporation of emerging technologies ensures that the standard remains relevant in a fast-evolving technological landscape, proving to be an invaluable asset for manufacturers and service providers alike.