Mounting
Installation with | The clamps and grub screws required for installation are supplied with | |
clamp fixing | the device. Proceed as follows: | |
| 1. | Insert the complete operating unit and computing unit into the moun- |
|
| ting |
|
| front. |
| 2. | From the rear, fix the operating unit in position in the mounting cut- |
|
| out using the six clamps (see Figure |
|
| screws (torque 0.4 - 0.5 Nm). |
Installation with | The 12.1º touchscreen version is not suitable for installation with screw | |
screw fixing | fixings. With the other operating units, proceed as follows: | |
| 1. | Drill suitable holes around the prepared mounting |
|
| Section 3.1) as specified for L4 and L5 in Figure |
| 2. | Carefully knock out the drill hole covers on the front side of the ope- |
|
| rating unit: |
Drill hole covers
3.Working from the front, insert the complete operating unit and com- puting unit into the mounting cutout, ensuring that is flush with the drill holes.
4.Fix the operating unit at the drill holes using suitable screws and nuts.
3.2.2Panel PC 870
The operating unit can be fitted in the mounting
Protection class IP 65 is possible when the operating unit is secured with clamps (in conjunction with a continuous gasket).
Protection class IP 54 is achieved with screw fixings.
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual | |
Edition 07/01 |