RL-854 Radio Control Unit

 

 

Type I, Style A

Description

 

Equipment Specification Data

 

 

(contd.)

 

 

 

 

Table 2. Equipment Information

 

 

Equipment

Specification

 

 

 

 

 

 

Style A Decoder

 

 

 

 

 

 

 

Construction

Plug-in circuit board

 

 

 

 

 

 

Response

Receiver pulses. Decoder remains non-responsive unless three or more pulses are

 

 

 

received in a 5-second interval. Only one relay stays powered, determined by the

 

 

 

number of pulses sent to the receiver:

 

 

 

Ø 3 pulses closes the 3-pulse relay.

 

 

 

Ø 5 pulses closes the 5-pulse relay and opens the 3-pulse relay.

 

 

 

Ø 7 pulses closes the 7-pulse relay and opens the 5-pulse relay.

 

 

 

Decoder does not respond to signal elements of less than 50 milliseconds and does

 

 

 

not require signal elements of more than 100 milliseconds.

 

 

 

 

 

 

Relay Response

Field-changeable to operate the relays in the following sequence, by removing

 

 

 

diodes D3, D4, and D12.

 

 

 

Ø 3 pulses closes the 3-pulse relay.

 

 

 

Ø 5 pulses closes the 3- and 5-pulse relays.

 

 

 

Ø 7 pulses closes the 3-, 5-, and 7-pulse relays.

 

 

 

 

 

 

Timer

Holds the relay(s) closed for 15 minutes. In fast test mode, timer releases relays

 

 

 

after 20 seconds.

 

 

 

 

 

 2001 Siemens Airfield Solutions, Incorporated

96A0027L

Page 8

All rights reserved

Issued 5/01

 

Page 13
Image 13
Siemens RL-854 manual Equipment Specification Data