RL-854 Radio Control Unit

 

 

Type I, Style A

 

Operation

Startup Procedures (contd.)

4.

Action: Wait approximately 20 seconds.

 

 

Result: The 3-pulse relay should open.

 

5.

Action: Depress Test Pushbutton S3 five times within 5 seconds.

 

 

Result: The 5-pulse relay should close.

 

6.

Action: Wait approximately 20 seconds.

 

 

Result: The 5-pulse relay should open.

 

7.

Action: Depress Test Pushbutton S3 seven times within 5 seconds.

 

 

Result: The 7-pulse relay should close.

 

8.

Action: Wait approximately 20 seconds.

 

 

Result: The 7-pulse relay should open.

 

9.

Action: Return Timer Test Switch S2 to NORMAL.

 

 

Result: Unit is now ready for operation.

NOTE: Each time Test Pushbutton S3 is depressed, carrier light DS2 should turn on.

 2001 Siemens Airfield Solutions, Incorporated

96A0027L

Page 27

All rights reserved

Issued 5/01

 

Page 32
Image 32
Siemens RL-854 manual Startup Procedures contd