SieMo S50037 Data Book PRELIMINARILY

Electrical Characteristics

Absolute Maximum Ratings

Rating

Min.

Max.

Storage Temperature

-30°C

+85°C

Supply Voltage Vcc (no damage)

-7V

+7V

Supply Voltage Vcc-IO

0V

+3.6V

5V Tolerant Terminals

-0.4V

+5.5V

Other Terminals

-0.4V

+3.55V

Input Rf Power, in band

 

5dBm

Recommended Operating Conditions

Operating Condition

Min.

Max.

Ambient Temperature Range 1

0°C

+40°C

Supply Voltage, Vcc

+3.2V

+6V

Supply Voltage, Vcc -IO

3V

3.4V

Timing Characteristics

Parameter

Min.

Typ.

Max.

Unit

System start up time from Power on

 

1230

 

ms

RESET# signal duration

 

2

 

ms

I/O Terminal Characteristics

 

 

 

 

Vcc = 3.3V unless otherwise stated

 

 

 

 

Digital Terminals

Min.

Typ.

Max.

Unit

Input Voltage:

 

 

 

 

VIL input logic level low

-0.4

-

0.3 Vcc_IO

V

VIH input logic level high

0.7 Vcc_IO

-

Vcc_IO + 0.4

V

Input Current:

-1

 

 

 

CMOS input (VI =3.3V or 0V)

-

1

µA

CMOS input + pull-up (VI =3.3V or 0V)

-20

-

-125

µA

CMOS input + pull-down (VI =3.3V or

20 / 2 1,2

-

125

µA

0V)

 

 

 

 

Output Voltage:

-

-

0.2

V

VOL output logic level low (IO = 4.0mA)

VOH output logic level high (IO = -4.0mA)

Vcc_IO-0.2

-

-

V

Tri-state Leakage Current:

 

 

 

 

IOZL (VI = 0V)

-1

-

1

µA

IOZH (VI = 3.3V)

-1

-

1

µA

CI Input Capacitance

2.5

-

10

pF

Power-on Reset

Min.

Typ.

Max.

Unit

Vcc falling threshold

2.35

2.45

2.55

V

Vcc rising threshold

2.50

2.60

2.70

V

Hysteresis

130

150

170

mV

USB Terminals

 

 

 

 

Input thresholds:

 

 

 

 

1The module is qualified for this temperature range. Functionality has been tested form –40 to +80° with a small number of samples. Components are specified form –20°C to 70°C. Radio performance decreases with rising temperature.

2PIO terminals have weak pull-down resistors (1/10th current of standard pull-down resistors).

8/30

Page 8
Image 8
Siemens S50037 manual Electrical Characteristics, Absolute Maximum Ratings, Recommended Operating Conditions