Technical specifications
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19 277

Table 10- 3 Electrical data

Device type
SCALANCE
Power supply
2 x 12 ... 24 VDC
(10 ... 30 VDC)
SELV (Safety Extra
Low Voltage)
Power loss at 12 VDC Current consumption
at rated voltage
Overcurrent protection at
input
Non-replaceable fuse (F)
X204-2TS + 6.60 W 0.6 A 3.0 A / 32 V

Device type
SCALANCE
Power supply
2 x 24 VDC
(18 ... 32 VDC)
SELV (Safety Extra
Low Voltage)
Power loss at 24 VDC Current consumption
at rated voltage
Overcurrent protection at
input
PTC resettable fuse
XF204 + 2.64 W 110 mA 1.1 A / 33 V
X208 + 3.84 W 160 mA 0.6 A / 60 V
XF208 + 3.12 W 130 mA 1.1 A / 33 V
X216 + 5.76 W 240 mA 1.1 A / 33 V
X224 + 8.40 W 350 mA 1.1 A / 33 V
X204-2 + 6.36 W 265 mA 0.6 A / 60 V
XF204-2 + 5.28 W 220 mA 1.1 A / 33 V
X206-1 + 5.28 W 220 mA 0.6 A / 60 V
XF206-1 + 4.08 W 170 mA 1.1 A / 33 V
X212-2 + 7.92 W 330 mA 1.1 A / 33 V
X204-2LD + 6.36 W 265 mA 0.6 A / 60 V
X206-1LD + 5.28 W 220 mA 0.6 A / 60 V
X212-2LD + 7.92 W 330 mA 1.1 A / 33 V
X202-2IRT + 6.0 W 300 mA 0.6 A / 60 V
X204IRT + 4.8 W 200 mA 0.6 A / 60 V
XF204IRT + 4.8 W 200 mA 0.6 A / 60 V
X204 IRT PRO + 4.8 W 200 mA 0.6 A / 60 V
X202-2P IRT PRO + 7.2 W 300 mA 1.1 A / 33 V
X201-3P IRT PRO + 7.2 W 300 mA 1.1 A / 33 V
X202-2P IRT + 7.2 W 300 mA 1.1 A / 33 V
X201-3P IRT + 8.4 W 350 mA 1.1 A / 33 V
X200-4P IRT + 9.6 W 400 mA 1.1 A / 33 V