ERROR CODES
AND DIAGNOSTICS
UNILINK HOST
ADAPTER 6–4
USER MANUAL
2009
The device addressed in the command string was not an HIU.
200A There is not enough memory for the number of secondary devices
specified with the maximum secondary address parameter. The
maximum secondary address defaults to 254. If you will not be using
this many devices, you can save memory space by specifying a value
equal
to the number of devices in your TIW
A
Y I network plus a few
for
growth.
See the CONFIGURE ADAPTER command, code 20.
2010 You tried to allocate a Source Id with a value of 0. The valid range for
Source
Ids is 1 to 255 (01 to FF hex).
2011 You
have already allocated 32 Source Ids. Y
ou will have to use a Source
Id that has already been allocated or clear a Source Ids resources to
begin
another
. Y
ou can get a list of the Source Ids already allocated with
the
REPORT MEMOR
Y USAGE command, code 18.
2012 The Source Id specified in the command string has not been allocated.
Check the Source Id value and use the ALLOCATE SOURCE ID
command,
code 10, to allocate it if necessary
.
2013 The macro type specified in the command string is invalid. The valid
macro
types are 01, 02, and 03.
2014 The
macro command buffer is too small for the macro specified with the
DEFINE
MACRO command. Y
ou will need to shorten the macro data or
allocate another macro buffer with sufficient size. Remember that
macro buffers cannot be explicitly deleted. You must deallocate the
Source
Id or reset the adapter to recover macro buffers.
2015 The
macro buffer number in the command string has not been
allocated.
Verify the macro buffer number and issue the ALLOCATE MACRO
STORAGE
BUFFERS command, code 13, if necessary
.
2016 The macro buffer number in the command string is already enabled.
This error will be returned when you try to redefine or initialize the
response
buffer of a macro that is currently enabled.
2017 The Source Id in the macro buffer did not match the Source Id in the
command string. Check the Source Id number and reissue the
command
with the correct value.
2018 The
INITIALIZE MACRO RESPONSE BUFFER command,
code 17, is
not
valid because this is a non-repetitive macro.