8. APPENDICES

Model 4501-XX Toxic Gas Sensor Module

8. APPENDICES

APPENDIX A: SPECIFICATIONS

Specifications:

Sensor:

 

4501-04

4501-05
4501-06

Max. Range (1)

0-1200 PPM

0-100 PPM

0-10 PPM

Zero Drift

+/- 1 PPM

+/- 0.5 PPM

+/- 0.5 PPM

Repeatability

+/- 1 PPM

+/- 1 PPM

+/- 0.5 PPM

Linearity

+/- 1 PPM

+/- 1 PPM

+/- 0.5 PPM

Resolution

0.5 PPM

0.1 PPM

0.1 PPM

Response Time (2)

<25 sec.

<30 sec.

<60 sec

Sensor Life (3)

2 years

2 years

2 years

(1)Optional ranges available

(2)Response time to 90% full signal value for applied concentration

(3)Sensor life typical for use at standard temperature and pressure with occasional exposure to gas of interest

Output:

 

 

 

 

 

 

 

Display:

 

LCD, 2-line, 20-characters

 

 

 

Signal Output:

 

2-wire sensor powered analog 4-20 mA (Trouble: 3.6 mA)

 

Loop Resistance

 

800 ohm

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Data:

 

 

 

 

 

 

 

Power consumption:

 

<160 milliwatts

 

 

 

Connection type:

 

2 wire

 

 

 

 

 

Input voltage:

 

24 VDC nominal: 14-30VDC, 2-wire loop powered

 

RFI/EMI Protection:

 

EN50081-2, EN50082-2

 

 

 

 

 

 

 

 

 

 

 

Operating Range:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4501-04 CO

 

4501-05 H2S

 

4501-06 Cl2

 

 

Ambient Temp (oF)

 

-4 to 122 oF

 

-40 to 122 oF

 

-4 to 122 oF

 

 

Ambient Temp (oC)

 

-20 to 50 oC

 

-40 to 50 oC

 

-20 to 50 oC

 

 

Relative Humidity

 

5 – 99%

 

5 – 99%

 

5 – 99%

 

 

Extended Range

 

Sensor and 4-20 mA will continue to operate to -40oF (-40oC) but the

 

Operation

 

LCD display will decay over time if exposed to temperatures below -4o(-

 

 

 

 

20o C) for significant time

 

 

 

Storage Temperature:

-4oto 122 oF(-20oto 50oC)

 

 

Enclosure:

 

 

 

 

 

 

 

Dimensions:

 

7.0 x 3.6 x 4.0 inches (H x W x D)

 

 

 

 

 

 

(17.8 x 9.1 x 11.2 cm)

 

 

 

Weight:

 

4.4 lb. (2.0 Kg)

 

 

 

Material of Construction:

316 Stainless Steel

 

 

 

Enclosure:

 

NEMA 4X

 

 

 

 

 

 

 

 

 

 

 

Electrical Classification:

 

 

 

 

 

 

 

FM Approved:

 

Explosion proof, Class 1, Div. I, Groups B, C, D

 

 

 

 

Class 1, Zone 1, Group IIB+H2 IP66

 

 

 

 

 

 

 

 

 

Approvals:

 

 

 

 

 

 

 

FM Performance Approval:

Approval Standards: ISA-92.0.01, Part I-1998 and FM 3600

 

(4501-05 only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote Sensor Option:

 

 

 

 

 

 

 

Distance Sensor to Transmitter:

4501-04

25 feet

 

 

 

 

 

 

4501-05

25 feet

 

 

 

 

 

 

4501-06

15 feet

 

 

Page: 18

Page 22
Image 22
Sierra Monitor Corporation 4501-06 Appendices, Appendix A Specifications, Model 4501-XXToxic Gas Sensor Module, Page