1. PRODUCT DESCRIPTION

Model 4501-XX Toxic Gas Sensor Module

1. PRODUCT DESCRIPTION

1.1GENERAL

The Model 4501-XX Toxic Gas Sensor Module is a 2-wire transmitter with 4-20 mA output and it offers a broad array of features including:

2-wire loop powered

180 day calibration interval

Selectable ranges

Non-intrusive one-person calibration

Integral LCD 2-line, 20-character display

Stainless steel enclosure and sensor housing

4-20 mA output

Long sensor life

Rotatable faceplate enables multi-directional installation attitudes.

The 4501-XX is designed and approved for installation and operation in hazardous locations.

Members of the 4501-XX Two-Wire Toxic Gas family include:

4501-04 Carbon Monoxide Gas Sensor Module

4501-05 Hydrogen Sulfide Gas Sensor Module

4501-06 Chlorine Gas Sensor Module

1.2MOUNTING CONFIGURATION

Various module mounting configurations can be implemented without special fixtures. Where applicable, these options are factory configured prior to shipment. Mounting configuration can be selected by the installer or field technician and are fully described in this manual.

1.3THEORY OF OPERATION

Electrochemical sensors are fuel cell-like devices consisting of an anode, cathode, and electrolyte. The components of the cell are selected so a subject gas, allowed to diffuse into the cell, will cause a chemical reaction and generate a current. The cells are diffusion limited so the rate the gas enters the cell is solely dependent on the gas concentration. The current generated is proportional to the rate of consumption of the subject gas in the cell.

Sierra Monitor electrochemical sensors provide improved reliability by allowing the gas to diffuse into the sensor through a capillary port, rather than diffusing through membranes. The result is an extremely stable sensor with very low temperature and pressure coefficients and the capability to monitor gas as ppm.

Page: 1

Page 5
Image 5
Sierra Monitor Corporation 4501-04, 4501-06, 4501-05 Product Description, Page, Model 4501-XXToxic Gas Sensor Module