Ember Light Replacement Bulb
In the lower gas valve compartment you will find three ac- cess panels for the three light bulbs (see Figure 54).
ACCESS PANEL
Figure 54.
Using a 5/16” nut driver remove the two bolts (see Figure 55).
ACCESS PANEL
Figure 55.
Pull the access panel to expose the light bulb. Wearing clean cotton gloves replace the bulb. Any skin oils which get on a new bulb will greatly shorten the life of the bulb. The bulb can be cleaned with isopropyl alcohol (see Figure 56).
Figure 56
Step 11. Before Lighting the Fireplace
Before lighting the fireplace, be sure to do the following:
Remove all paperwork from underneath the fireplace. Review safety warnings and cautions
•Read the Safety and Warning Information section at the beginning of this Installers Guide.
•Before lighting the fireplace,
•Before lighting the fireplace,
•Any component that is found to be faulty MUST BE re- placed with an approved component. Tampering with the fireplace components is DANGEROUS and voids all war- ranties.
A small amount of air will be in the gas supply lines. When first lighting the fireplace, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the fireplace will light and will operate normally.
Subsequent lightings of the fireplace will not require this purging of air from the gas supply lines, unless the gas valve has been turned to the OFF position, in which case the air would have to be purged.
NOTE: The fireplace should be run 3 to 4 hours on the initial
During this
Step 12. Lighting the Fireplace
You’ve reviewed all safety warnings, you’ve checked the fireplace for gas leaks, you know the vent system is unobstructed, and you’ve checked for faulty components. Now you’re ready to light the fireplace.
WARNING: PLEASE REFER TO THE USER’S
!MANUAL FOR ALL CAUTIONS, SAFETY, AND WARNING INFORMATION PERTAINING TO THE LIGHTING AND OPERATION OF THE FIREPLACE.
After the Installation
LEAVE THIS INSTALLATION MANUAL WITH
!THE APPLIANCE FOR FUTURE REFERENCE.
37 |