Quadra-Fire QV-ST, QV-PIER Wiring the Fireplace, For Intermittent Pilot Ignition Wiring

Models: QV-ST QV-PIER

1 41
Download 41 pages 18.24 Kb
Page 31
Image 31
Step 8. Wiring the Fireplace

BULB SOCKET

ASSEMBLY (3)

PLUG-IN

3V TRANSFORMER

ON/OFF

WALL SWITCH

FLAME SPARKER/

SENSOR

IGNITION

 

WHT

MODULE

 

 

 

(3V)

 

 

 

 

BLK

VALVE

LOW VOLTAGE

 

 

SEE NOTE 1

WHT

 

 

IGNITION MODULE 3 VAC

BLK

WHT

BLK

I

INTERMITTENT

PILOT IGNITOR

S

WHT

ORG

GROUND TO

FIREPLACE

CHASSIS

NEUTRAL

GROUND REMOTE

 

CONTROL HOT

Note: An alternate electronic ember switch can be installed on the wall by connecting a minimum 18 gage Romexto the leads supplied on the back of the electric ember switch.

ELECTRONIC EMBERS

BLK

SCALE 1/1

TERMINAL BLOCK

TRANSFORMER 3 VAC

WHT

ORG

GRN

FLAME ON/OFF

BLACK WIRE CAN BE

PLUGGED INTO ANY OF

#1 - #5 LOCATIONS

ON THE HOT SIDE

WHITE WIRE

CAN BE

PLUGGED

INTO ANY

OF #1 - #5

LOCATIONS

ON THE

NEUTRAL

SIDE

PLUG IN

VALVE

LCOR & RCOR JUNCTION BOX

Figure 34. Intermittent Pilot Ignition (IPI) Wiring Diagram

Step 8. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENTAL FIREPLACE OPERATION.

For Intermittent Pilot Ignition Wiring

Appliance Requirements

This appliance requires that 110-120 VAC be wired to the junction box. Maintain correct polarity when wiring the junc- tion box.

Operation using Battery Power

This fireplace has an optional battery operation. The sys- tem is fully functional with the use of two “D” size batteries without ordinary 110-120 VAC power.

Wiring to the battery pack should be left disconnected in order to conserve battery life. In the case of a loss of power, simply connect red and black wire leads to activate battery power (connect red to red, black to black). The fireplace can be used as necessary. Once power (110 VAC) is re- stored, disconnect red and black wire leads to extend bat- tery life.

Quadra-FireQV-PIER, QV-ST Series: HV-IPI2005-901 Rev. G • 2/06

31

Page 31
Image 31
Quadra-Fire QV-ST, QV-PIER owner manual Wiring the Fireplace, For Intermittent Pilot Ignition Wiring, Appliance Requirements