Quadra-Fire QV-ST, QV-PIER owner manual Venting with One 90 Elbow

Models: QV-ST QV-PIER

1 41
Download 41 pages 18.24 Kb
Page 19
Image 19
Figure 13. Venting with One 90° Elbow

NATURAL GAS - VENTING WITH ONE 90° ELBOW

 

V (FT.)

H (FT.)

 

1' MIN. (305mm)

3' MAX. (914mm)

 

2' MIN. (610mm)

6' MAX.

(1.83m)

 

3' MIN. (914mm)

9' MAX.

(2.7m)

 

4' MIN. (1.22m)

12' MAX.

(3.6m)

 

5’ MIN. (1.5m)

15’ MAX.

(4.5m)

 

6’ MIN. (1.83m)

18’ MAX.

(5.5m)

 

V + H = 50’ MAX. (15.2m)(11.3m)

 

PROPANE - VENTING WITH ONE 90° ELBOW

 

V (FT.)

H (FT.)

 

1' MIN. (305mm)

2' MAX. (610mm)

V

2' MIN. (610mm)

4' MAX.

(1.22m)

 

3' MIN. (914mm)

6’ MAX. (1.83m)

 

4' MIN. (1.22m)

8' MAX.

(2.4m)

 

5’ MIN. (1.5m)

10' MAX.

(3.0m)

 

6’ MIN. (1.83m)

12' MAX.

(3.6m)

 

V + H = 50’ MAX. (15.2m)

 

H

 

 

 

Figure 13. Venting with One 90° Elbow

 

 

 

 

 

H

 

 

 

 

 

 

 

 

V

NATURAL GAS

 

 

PROPANE

 

 

VENTING WITH ONE 90° ELBOW

VENTING WITH ONE 90° ELBOW

 

V (FT.)

H (FT.)

V (FT.)

H (FT.)

 

900 Elbow on top

2.5’ MAX. (64mm)

900 Elbow on top

2’ MAX. (610mm)

 

1' MIN. (305mm)

3' MAX. (914mm)

1' MIN. (305mm)

2' MAX. (610mm)

 

2' MIN. (610mm)

6' MAX.

(1.83m)

2' MIN. (610mm)

4' MAX.

(1.22m)

 

3' MIN. (914mm)

9' MAX.

(2.7m)

3' MIN. (914mm)

6’ MAX.

(1.83m)

 

4' MIN. (1.22m)

12' MAX.

(3.6m)

4' MIN. (1.22m)

8' MAX.

(2.4m)

 

5’ MIN. (1.5m)

15’ MAX.

(4.5m)

5’ MIN. (1.5m)

10' MAX.

(3.0m)

 

6’ MIN. (1.83m)

18’ MAX.

(5.5m)

6’ MIN. (1.83m)

12' MAX.

(3.6m)

 

V + H = 50’ MAX. (15.2m)

V + H = 50’ MAX. (15.2m)

 

Figure 14. Venting with One 90° Elbow

 

 

 

 

 

Quadra-FireQV-PIER, QV-ST Series: HV-IPI2005-901 Rev. G • 2/06

19