15.0Insert the Flue Support Bracket (IB1100 Only):

13

15.0Insert the Flue Support Bracket (IB1100 Only):

Place the Flue Support Bracket in line with the flue hole on the Top-Rear panel. The Flue should be ready to pass through the hole in the OSK and mate with the Gas Fire Spigot. The Flue Liner should rest on top of the Flue Support Bracket and self locate.

16.0Preparing the Heater for Installation:

The spacer brackets on the top, sides and back of heater MUST be bent and re-fixed as per instructions in section 2.3, before the heater is pushed into any non-masonry cavity.

The heater can now be pushed into the cavity or Outer Skin Kit (IB1100). If any of the spacer brackets contact any combustible material then the cavity must be re-sized to accommodate the heater and maintain the clearances listed in Section 2.0 of this manual.

Please consider how the fire will be fixed to the base before installing. Refer to 21.0 for details

17.0Removing the Front Glass:

Step 1: Unscrew the side (where fitted) and top glass retainers and remove them. Take care that the glass does not fall forwards at this stage