Sim2 Multimedia HT500 LINK installation manual Connecting The Two Units

Models: HT500 LINK

1 40
Download 40 pages 43.62 Kb
Page 12
Image 12
CONNECTING THE TWO UNITS

CONNECTING THE TWO UNITS

The system can be fully controlled using the supplied IR (infra- red) remote control handset. There is a single remote control for both the DigiOptic™ Image Processor and the Projector; the remote control can be directed towards either unit since they are both equipped with an IR sensor.

The connection between the two units is made with a single cable containing three fibre optic cables each terminating in an LC connector. The standard cable length of 20m will be sufficient for most installation requirements.

During installation of the fibre optic cable:

Check that the connectors are correctly inserted.

Make sure that the cable does not constitute an obstacle for persons moving around the room.

Take care not to create knots in the cable; the minimum radius of bends in the cable is 2 cm.

Prevent the cable from pulling and mechanical stress: this could cause the connectors to be pulled out and dama- ged.

The individual optical cables are delicate: always handle the main cable without touching the individual optical ca- bles (Fig. 7).

Never pull the individual optical cables or connectors; if necessary, you may pull the main three-core cable.

Protective cap

12

 

(RS

232)

 

-

CONTROL

 

3

 

2

 

 

 

1

 

 

 

 

LINK

FIBER

 

OPTICAL

 

 

3 Fig.8

Fig.9 3

Protective cap

Separation point

Ferrule

Connector

Fig.8

Protective cap

Fibre

CableFig.7

Only remove the cap protecting the connector ferrule im- mediately before inserting the connector; if the ferrule is allowed to come into contact with foreign material it may be damaged, making the connector unusable.

Take particular care when inserting fibre optic connectors in their respective sockets on the rear panel of the DigiOptic™ Image Processor and the rear panel of the Projector.

Make sure that the single optical cables are not switched: the numbers on the cables must match the numbers on the connectors (Fig.8-9).

Fig.9

10