1

INSTALLATION

CONNECTING THE TWO UNITS

SIM2’s RTX system is made up of the following components (Fig.1):

Display

DigiOptical Image Processor

remote control

DigiOptical Image Processor power supply unit

three power cables for the Display

three power cables for the DigiOptical Image Processor

triple fibre optic cable for linking the DigiOptical Image Processor and the Display

four 1.5 V AAA-type batteries for the remote control

User and installation manual

If any accessories are missing, contact your Dealer as soon as possible.

Display

Instruction

Manual

I

O

Alimentatore

DigiOptical Image

DigiOptical

ProcessorImage Processorpower supply unit

DI

 

 

 

GIO

PTIC

 

 

 

ALIM

AGE

 

 

 

 

 

 

PRO

CESSOR

 

 

 

Three-core

DigiOptical

fibre optic cable

Image Processor

Remote Control

1.5 V AAA- type batteries

Power cables

Europe, UK, US (x2)

Fig. 1

The RTX system consists of two separate units (the DigiOptical Image Processor and the Display), each of which is equipped with a power cable; the two units are interconnected by a 20 m fibre optic cable.

The ideal location for the DigiOptical Image Processor is on a cabinet shelf or on a rack (dimensions compatible with a standard 19" rack). Make sure that the support surface is stable and that the unit has sufficient space around it for ventilation purposes (at least 3 cm).

The unit is connected to the mains via an external power supply unit with an output of +7 Vdc; the unit’s main power switch is on the power supply unit.

Connect the power supply unit output cable to the POWER socket located on the rear panel (Fig. 4).

Use exclusively the power supply unit provided with the system or an alternative power supply unit expressly approved by SIM2.

The Display is designed to stand on the floor. Place the Display on a flat, level surface where it has sufficient space for ventilation; to prevent glare and reflections, avoid places exposed to direct sunlight or intense light sources.

The mains power input socket and the power switch are both located on the rear panel.

Adjust the rear feet to obtain the optimum viewing angle in accordance with the distance and height of the viewing position in front of the Display (Fig. 2).

The system can be fully controlled using the supplied IR

Fig. 2

(infrared) remote control handset. There is a single remote control for both the DigiOptical Image Processor and the Display; the remote control can be directed towards either unit since they are both equipped with an IR sensor.

The connection between the two units is made with a single cable containing three fibre optic cables each terminating in an LC connector. The standard cable length of 20 m will be sufficient for most installation requirements.

Tappo di

Pprotezionective cap

Ferrule

Separation point

Connector

Fibre

Fig. 3

Cable

6