Simer Pumps 2.81E+01 owner manual Installation, Replacing An Old Pump, ca e

Models: 2.81E+01

1 28
Download 28 pages 29.76 Kb
Page 4
Image 4
Installation

Installation

4

 

 

To Household

Pump Priming

Water System

Tee and Plug

Priming

Tee and

Plug

Check

Valve

Drive point below water level

Drive Typical pump Point shown hereinca e

Coupling Replacing An Old PumpWell Point (Driven Point) Installation (Figure 1)Manual backgroundManual backgroundManual background

Drive

Typical pump Point shown herein

not to scale

ca e

Figure 1: Driven Point Installation

To Household

 

Pump Priming

Water System

 

 

 

Tee and Plug

 

 

Suction Pipe

 

 

From Well

 

 

 

 

 

 

 

Priming

 

 

Tee and

 

 

Plug

 

 

Sanitary

 

 

Well Seal

10' Foot

Min. Valve

5–10' Manual background

Figure 2: Cased Well Installation

Replacing An Old Pump

Manual background Hazardous voltage.. Disconnect power to pump before working on pump or motor.

1.Drain and remove the old pump. Check the old pipe for scale, lime, rust, etc., and replace it if necessary.

2.Install the pump in the system. Make sure that all pipe joints in the suction pipe are air-tight as well as water tight. If the suction pipe can suck air, the pump will not be able to pull water from the well.

3.Adjust the pump mounting height so that the plumbing connections do not put a strain on the pump body. Support the pipe so that the pump body does not take the weight of piping or fittings.

You have just completed the well plumbing for your new shallow well jet pump. Please go to Page 6 for discharge pipe and tank connections.

Well Point (Driven Point) Installation (Figure 1)

1.Drive the well, using “drive couplings” and a “drive cap”. “Drive fittings” are threaded all the way through and allow the pipe ends to butt against each other so that the driving force of the maul is carried by the pipe and not by the threads. The ordinary fittings found in hardware stores are not threaded all the way through the fitting and can collapse under impact. “Drive fittings” are also smoother than standard plumbing fittings, making ground penetration easier.

2.Mount the pump as close to the well as possible.

3.Use the fewest possible fittings (especially elbows) when connecting the pipe from the well point to the pump suction port. The suction pipe should be at least as large as the suction port on the pump (include

a check valve if your pump is not equipped with one – see Figure

1). Support the pipe so that there are no dips or sags in the pipe, so it doesn’t strain the pump body, and so that it slopes slightly upward from the well to the pump (high spots can cause air pockets which can air lock the pump). Seal the suction pipe joints with 1Teflon™ tape or a Teflon™ based pipe joint compound. Joints must be air- and water- tight. If the suction pipe can suck air, the pump cannot pull water from the well. If one well point does not supply enough water, consider connecting two or three well points to one suction pipe.

You have just completed the suction piping for your new shallow well jet pump. Please go to Page 6 for discharge pipe and tank connections.

1E. I. DuPont de Demours and Company Corporation, Delware

Cased Well Installation, 2” or Larger Casing (Figure 2)

1.Mount the pump as close to the well as possible.

2.Assemble the foot valve, strainer, and well pipe (see Figure 2). Make sure that the foot valve works freely.

3.Lower the pipe into the well until the strainer is five feet above the bottom of the well. It should also be at least 10 feet below the well’s water level while the pump is running in order to prevent the pump from sucking air. Install a sanitary well seal.

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Page 4
Image 4
Simer Pumps 2.81E+01 owner manual Replacing An Old Pump, Well Point Driven Point Installation Figure, ca e