Sinclair ASH-09AK, ASH-13AK service manual Conventional 12 Disassembly procedures for indoor unit

Models: ASH-09AK ASH-13AK

1 49
Download 49 pages 2.17 Kb
Page 27
Image 27

(Conventional 12) Disassembly procedures for indoor unit

Operating Procedures / Photos

1. Disassemble the front panel, filter

Front Panel

Push the rotating shaft of front panel outwardly, to make it out of the groove, then can take down the front panel.

Filter

2. Disassemble the guide louver

Bend the guide louver so that the movable lock of guide louver is released to remove the guide louver.

Guide louver

3. Disassemble the front case

Open the 2 screw covers at the front case and screw off 1 screws. Pull out the movable latch at the front case with hand and then pull it back- wards to disassemble the front case.

Screws

Page 27
Image 27
Sinclair ASH-09AK, ASH-13AK service manual Conventional 12 Disassembly procedures for indoor unit