INSTALLATION

Deactivating the Digital Dialer

You can deactivate the digital dialer by erase the phone number memory for central monitoring station.

Step

Keys

Function

Description

Note

 

 

 

 

 

1

Press [PROG]

Enter Program-

Enter master

3 beeps for valid

 

Press [MPIN]

ming mode

password to

password. 1 long

 

 

 

programming mode

beep for invalid

 

 

 

 

password.

 

 

 

 

 

2

Press [1]

Select phone

 

You will hear:

 

number

 

[Enter Phone

 

 

 

 

 

programming

 

Memory]

 

 

 

 

 

3

Press [0]

Enter phone

 

 

 

 

memory

 

 

 

 

 

 

 

4

Press [ARM]

Confirm delete

 

You will hear

 

 

the phone

 

[Phone Zero

 

 

number.

 

Empty Memory]

 

 

 

 

indicating the phone

 

 

 

 

number have been

 

 

 

 

deleted, the digital

 

 

 

 

dialer is deactivated.

 

 

 

 

 

Note: If no phone number is programmed to call the central monitoring station, the digital dialer is automatically disabled.

14

HOME AUTOMATION

Control Module [1] is represented by zone LED 1

®

This row :

Buttons for

Learning Control Module

Part 2 Learn signal from Control Panel to Control Module

Step

 

Keys

 

Function

Description

Note

 

 

 

 

 

 

1

 

Press and hold

Enter

 

LED on the Control Module

 

 

the learn button

Programming

 

will flash indicating it is in

 

 

on the Control

 

mode

 

learn mode.

 

 

Module until its

 

 

 

 

 

 

LED starts to

 

 

 

 

 

 

 

flash.

 

 

 

 

 

 

 

 

 

 

 

 

2

 

[6] to [0]

 

Transmit an ON

Refer to the

After [X] is entered, you

 

 

 

 

signal for the

chart below to

will hear [Device X On]

 

 

 

 

 

 

 

 

 

 

selected device

determine which

indicating you have trans-

 

 

 

 

 

from the Control

button [6] to [0]

mitted an ON signal for

 

 

 

 

 

Panel to the

to press.

device X, where X is the

 

 

 

 

 

Control Module.

You should

Control Module Location.

 

 

 

 

 

 

 

transmit the “ON”

The LED on the Control

 

 

 

 

 

 

 

command for the

Module should be off,

 

 

 

 

 

 

 

selected device.

indicating it has learned

 

 

 

 

 

 

 

 

the signal, you may now

 

 

 

 

 

 

 

 

release the learn button

 

 

 

 

 

 

 

 

and the LED will stay on

 

 

 

 

 

 

 

 

again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL MODULE

 

TRANSMIT

 

 

 

LOCATION

 

 

BUTTON [X]

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

9

 

 

 

5

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

39

Page 16
Image 16
SkyLink AM-002/ML-001 manual Deactivating the Digital Dialer, Part 2 Learn signal from Control Panel to Control Module