Slant/Fin B-120A Viewing and Changing Temperatures, steps of 1 F. The default valve is 140˚ F

Models: B-200A B-120A

1 12
Download 12 pages 32.3 Kb
Page 10
Image 10
Table 2: Viewing and Changing Temperatures

Bobcat Model B-120A and B-200A

10

Table 2: Viewing and Changing Temperatures

Press “Select” button for viewing different modes on “Mode Display”

Table 2

Table 2

Table 2

Table 2 Table 2

Mode

 

Description & Temperature Display

Display

 

 

 

 

 

Space heating supply water temperature could be

 

Blinking

changed by pressing “Up/Down” button. Settable from

 

90˚F to 185˚F (steps of 1 F). The default valve is 176˚ F

 

 

 

 

Press “Enter” button to store. (see note 1)

 

 

Domestic hot water supply temperature could be changed

 

 

by pressing “Up/Down” button. Settable from

 

Blinking

104˚F to 185˚F (steps of 1 F). The default valve is 176˚ F

Table 1

 

 

Press “Enter” button to store.

 

Table 3

(see note 2)

 

 

Table 1

 

 

 

Table 3

 

 

 

 

Table 1

 

Domestic hot water tank temperature could be changed by

Table 1

 

Table 3

 

Blinking

pressing “Up/Down” button. Settable from 104˚F to 160˚F

Table 1

Table 3

 

 

Table 3 (steps of 1 F). The default valve is 140˚ F.

 

 

 

 

Press “Enter” button to store. (see note 3)

 

 

 

Temperature display shows actual

 

 

 

supply water temperature.

 

 

 

Temperature display shows actual

 

 

 

return water temperature.

Temperature display shows actual DHW tank temperature.

(if the water tank is equipped with sensor)

Temperature display shows actual flue gas temperature.

Temperature display shows actual outside temperature.

(boilers with outdoor sensor)

Table 2

Notes:

1.For space heating mode “0” (boilers not utilizing outdoor sensor)

2.For DHW mode “2” (storage tank with Aquastat)

3.For DHW mode “1” (storage tank with sensor)

Page 10
Image 10
Slant/Fin B-120A Viewing and Changing Temperatures, steps of 1 F. The default valve is 140˚ F, boilers with outdoor sensor