SMC Networks SMC7824M/FSW manual Selecting a Site, Installing The Switch

Models: SMC7824M/FSW

1 108
Download 108 pages 34.55 Kb
Page 41
Image 41
CHAPTER 3 INSTALLING THE SWITCH

CHAPTER 3 INSTALLING THE SWITCH

Selecting a Site

TigerAccess 10/100 units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location.

The site should:

-restrict access to authorized service personnel in accordance with IEC 60950-1. A restricted access location is one where access is secure and limited to service personnel who have a special key, or other means of security.

-be at the center of all the devices you want to link and near a power outlet.

-be able to maintain its temperature within 0 to 50 °C (32 to 122 °F) and its humidity within 5% to 95%, non-condensing

-provide adequate space (approximately five centimeters or two inches) on all sides for proper air flow

-be accessible for installing, cabling and maintaining the devices

-allow the status LEDs to be clearly visible

Make sure twisted-pair cable is always routed away from power lines, fluorescent lighting fixtures and other sources of electrical interference, such as radios and transmitters.

Make sure that the unit is connected to a separate grounded power outlet within 2 m (6.6 feet) of each device and is powered from an independent circuit breaker. As with any equipment, using a filter or surge suppressor

3-1

Page 41
Image 41
SMC Networks SMC7824M/FSW manual Selecting a Site, Installing The Switch