INSTALLING THE SWITCH

Wiring Map for Alarm Cable

The signals include relay contacts for major and minor system alarms, and external alarm inputs.

Table 3-2 Alarm Cable Wiring

Switch’s Alarm Port

Function

 

 

 

1

(MJR_ALARM_CNTR)

Common contact for major alarm relay.

 

 

 

2

(MNR_ALARM_CNTR)

Common contact for minor alarm relay.

 

 

 

3

(ALARM_IN3_EXT_P*)

External alarm input 3 (external relay dry

 

 

 

contact closure to pin 13).

 

 

 

4

(ALARM_IN4_EXT_P)

External alarm input 4 (external relay dry

 

 

 

contact closure to pin 8).

 

 

 

5

(No Contact)

 

 

 

 

6

(MJR_ALARM_NO)

Normally open during major alarm state.

 

 

 

7

(MNR_ALARM_NO)

Normally open during minor alarm state.

 

 

 

8

(ALARM_IN4_EXT_RTN)

External alarm input 4 (external relay dry

 

 

 

contact closure from pin 3).

 

 

 

9

(ALARM_IN1_EXT_P)

External alarm input 1 (external relay dry

 

 

 

contact closure to pin14).

 

 

 

10

(ALARM_IN2_EXT_P)

External alarm input 2 (external relay dry

 

 

 

contact closure to pin 15).

 

 

 

11

(MJR_ALARM_NC)

Normally closed during major alarm state.

 

 

 

12

(MNR_ALARM_NC)

Normally closed during minor alarm state.

 

 

 

13

(ALARM_IN3_EXT_RTN)

External alarm input 3 (external relay dry

 

 

 

contact closure from pin 3).

 

 

 

14

(ALARM_IN1_EXT_RTN)

External alarm input 1 (external relay dry

 

 

 

contact closure from pin 9).

 

 

 

15

(ALARM_IN2_EXT_RTN)

External alarm input 2 (external relay dry

 

 

 

contact closure from pin 10).

 

 

 

 

* P indicates positive input.

† RTN indicates return to Ground.