Twisted-Pair Cable and Pin Assignments B

You must connect all four wire pairs as shown in the following diagram to support Gigabit Ethernet connections.

EIA/TIA 568B RJ-45 Wiring Standard 10/100BASE-TX Crossover Cable

White/Orange Stripe

Orange

 

1

White/Green Stripe

1

End A

2

 

2

 

3

Blue

3

 

4

 

4

 

5

White/Blue Stripe

5

 

6

Green

6

 

7

7

 

 

 

8

White/Brown Stripe

8

 

 

 

End B

Brown

Figure B-3 Crossover Wiring

1000BASE-T Pin Assignments

All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.

The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These ports require that all four pairs of wires be connected. Note that for 1000BASE-T operation, all four pairs of wires are used for both transmit and receive.

Use 100-ohm Category 5, 5e or 6 unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for 1000BASE-T connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).

Table B-2 1000BASE-T MDI and MDI-X Port Pinouts

Pin

MDI Signal Name

MDI-X Signal Name

 

 

 

1

Bi-directional Pair A Plus (BI_DA+)

Bi-directional Pair B Plus (BI_DB+)

 

 

 

2

Bi-directional Pair A Minus (BI_DA-)

Bi-directional Pair B Minus (BI_DB-)

 

 

 

3

Bi-directional Pair B Plus (BI_DB+)

Bi-directional Pair A Plus (BI_DA+)

 

 

 

4

Bi-directional Pair C Plus (BI_DC+)

Bi-directional Pair D Plus (BI_DD+)

 

 

 

5

Bi-directional Pair C Minus (BI_DC-)

Bi-directional Pair D Minus (BI_DD-)

 

 

 

6

Bi-directional Pair B Minus (BI_DB-)

Bi-directional Pair A Minus (BI_DA-)

 

 

 

7

Bi-directional Pair D Plus (BI_DD+)

Bi-directional Pair C Plus (BI_DC+)

 

 

 

8

Bi-directional Pair D Minus (BI_DD-)

Bi-directional Pair C Minus (BI_DC-)

 

 

 

B-3

Page 51
Image 51