France and Peru only

This unit cannot be powered from ITsupplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an iso- lation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to earth (ground).

Impédance à la terre

Power Cord Set

U.S.A. and

Canada

Denmark

Switzerland

U.K.

Europe

The cord set must be UL-approved and CSA certified.

The minimum specifications for the flexible cord are:

-No. 18 AWG - not longer than 2 meters, or 16 AWG.

-Type SV or SJ

-3-conductor

The cord set must have a rated current ca- pacity of at least 10 A.

The attachment plug must be an earth-grounding type with NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.

The supply plug must comply with Section 107-2-D1, Standard DK2-1a or DK2-5a.

The supply plug must comply with SEV/ ASE 1011.

The supply plug must comply with BS1363 (3-pin 13 A) and be fitted with a 5 A fuse which complies with BS1362.

The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75 (minimum).

The supply plug must comply with CEE7/7 (“SCHUKO”).

The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75 (minimum).

IEC-320 receptacle.

Page 9
Image 9