France and Peru only
This unit cannot be powered from IT supplies. If your supplies are
of IT type, this unit must be powered by 230 V (2P+T) via an iso-
lation transformer ratio 1:1, with the secondary connection point
labelled Neutral, connected directly to earth (ground).
Impédance à la terre
Power Cord Set
U.S.A. and
Canada The cord set must be UL-approved and CSA
certified.
The minimum specifications for the flexible
cord are:
- No. 18 AWG - not longer than 2 meters, or
16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current ca-
pacity of at least 10 A.
The attachment plug must be an
earth-grounding type with NEMA 5-15P (15
A, 125 V) or NEMA 6-15P (15 A, 250 V)
configuration.
Denmark The supply plug must comply with Section
107-2-D1, Standard DK2-1a or DK2-5a.
Switzerland The supply plug must comply with SEV/
ASE 1011.
U.K. The supply plug must comply with BS1363
(3-pin 13 A) and be fitted with a 5 A fuse
which complies with BS1362.
The mains cord must be <HAR> or
<BASEC> marked and be of type
HO3VVF3GO.75 (minimum).
Europe The supply plug must comply with CEE7/7
(“SCHUKO”).
The mains cord must be <HAR> or
<BASEC> marked and be of type
HO3VVF3GO.75 (minimum).
IEC-320 receptacle.