France and Peru only
This unit cannot be powered from IT† supplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an iso- lation transformer ratio 1:1, with the secondary connection point labelled Neutral, connected directly to earth (ground).
† Impédance à la terre
Power Cord Set
U.S.A. and
Canada
Denmark
Switzerland
U.K.
Europe
The cord set must be
The minimum specifications for the flexible cord are:
-No. 18 AWG - not longer than 2 meters, or 16 AWG.
-Type SV or SJ
-
The cord set must have a rated current ca- pacity of at least 10 A.
The attachment plug must be an
The supply plug must comply with Section
The supply plug must comply with SEV/ ASE 1011.
The supply plug must comply with BS1363
The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75 (minimum).
The supply plug must comply with CEE7/7 (“SCHUKO”).
The mains cord must be <HAR> or <BASEC> marked and be of type HO3VVF3GO.75 (minimum).