WEB CONFIGURATION

Speed/Duplex Status – Shows the current speed and duplex mode.

10hdx: 10 Mbps half duplex.

10fdx: 10 Mbps full duplex.

100hdx: 100 Mbps half duplex.

100fdx: 100 Mbps full duplex.

1000fdx: 1000 Mbps full duplex.

Flow Control Status – Indicates whether flow control is enabled or disabled. (IEEE 802.3x, or Back-Pressure)

Autonegotiation – Shows if auto-negotiation is enabled or disabled.

Frame Type – Either “Tagged” or “All.” “Tagged” means that the port will only send and receive VLAN-tagged packets. When set to “All,” the port will also send and receive untagged packets.

PVID – The VLAN ID assigned to untagged frames received on the interface. (Default: 1)

Trunk Information

Trunk – The trunk label. “T1” through “T8” are used as trunk labels.

Type – All trunks and ports on this switch are 10/100/1000Mbps

Trunk Status – Indicates the speed and duplex setting of the trunk. This can be changed on the TRUNKS > Settings page.

10hdx: 10 Mbps half duplex.

10fdx: 10 Mbps full duplex.

100hdx: 100 Mbps half duplex.

100fdx: 100 Mbps full duplex.

1000fdx: 1000 Mbps full duplex.

Ports – The ports that are members of the trunk.

VLAN Inoformation

VLAN ID – A number in the range 1 - 4094 which identifies the VLAN.

VLAN Member – A list of the ports that are members of the VLAN. By default, all ports are members of VLAN 1.