Smeg A1-6 Instructions for the installer, Installation Of The Appliance, Electrical connection

Models: A1-6

1 31
Download 31 pages 22.52 Kb
Page 4
Image 4
Instructions for the installer

Instructions for the installer

2. INSTALLATION OF THE APPLIANCE

It is the law that all gas appliances are installed by competent persons. Corgi gas installers are approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990.

It may be installed against walls one of which is higher than the worktop surface, at least 50 mm from the side of the appliance, as shown in the installation class drawings A and B. Wall units or extractor hoods installed above the appliance's work-top must be at least 750 mm above it.

A

SLOT IN

FREE STANDING

2.1 Electrical connection

B

Make sure that the power line voltage matches the specifications indicated on the rating plate located inside the storage compartment.

This rating plate must never be removed.

The plug at the end of the power cable and the wall socket must be the same type (conforming to regulations in force). Check that the power line is adequately grounded. Do not use reducers, adapters or shunts.

On the power line, install an omnipolar cut-off device with contact cut-off distance greater than or equal to 3 mm, located in an easily accessible position near the unit.

If the power cable is replaced, the wire section on the new cable must not be less than 1.5 mm2 (3 x 1.5 cable), keeping in mind that the end to be connected to the hob must have the ground wire (yellow-green) longer by at least 20 mm. Use only the special cables available at our Service Centres.

38

Page 4
Image 4
Smeg A1-6 manual Instructions for the installer, Installation Of The Appliance, Electrical connection