For operation on 230-240V∼: use an

Instructions for the installer

The connection terminals are located at the rear of the appliance. For electrical connections see following diagram. To access, remove the rear cover.

For operation on 400-415V3N: use an H05RR-F-typefive-core cable (5 x 1.5 mm2).

For operation on 400-415V2N: use an H05RR-F-typefour-core cable (4 x 2.5 mm2).

For operation on 230-240V: use an

H05RR-F-type three-core cable (3 x 4 mm2).

The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer.

The manufacturer declines all responsibility for damage to persons or things caused by non-observance of the above prescriptions or by interference with any part of the appliance.