5. CHECKING OPERATION

Instructions for the Installer

5. CHECKING OPERATION

After having fastened the top to the support structure, some simple procedures are required to check for proper operation.

1)

Check for any gas leaks in the vicinity of the cooktop connector, the pressure regulator and the safety valve.

WARNING

FIRE HAZARD

- Use a soapy solution to check for proper tightness.

- Never test for gas leaks with a match or other flames.

-Failure to follow this instruction can result in death or fire

NOTE: The regulator Is fitted with a checkpoint outlet gas pressure to check the exact pressure supplied to the appliance.

2)

3)

Refit the crowns, flame caps and grids on the cooktop in the following order:

1 Fit the crowns, ensuring that they are perfectly locked into their housing on the cooktop.

2 Fit the flame caps on the crowns, ensuring that the edges match perfectly.

3 Fit the grids, making sure to fasten the side spokes in the special “A” seats found on the cooktop.

These procedures must be repeated for each burner on the cooktop.

CAUTION: refit all flame caps in the same points from which they were removed. In fact, the flame cap positions cannot be changed. After refitting them, ensure that they are fitted perfectly and that there is no clearance between the top and the flame caps.

The cooktop's electrical circuit can be checked for proper operation only after top assembly has been completed as described in step

2)and you have checked to ensure that all parts have been fitted properly:

1 a spark must light on all burners when the knobs on the top are pressed

2 when each knob on the cooktop is pressed and turned to the min flame symbol ( FIRE HAZARD ), the entire crown should light.

3 lf burners do not light properly, turn the control knob to the

"OFF" position - Never test for gas leaks with a match or other flames. . Check that burner caps and crowns are in the proper position. Check that the power supply cord is plugged in and that circuit breaker or house fuse has not blown. Check that the shut-off valve is in the "ON" position. Check operation again. lf a burner does not light at this point, contact your dealer for assistance.