Smeg XXSC111P manual Setting the cleaning cycle, Instructions for the User

Models: XXSC111P

1 32
Download 32 pages 42.37 Kb
Page 26
Image 26
11.6.3 Setting the cleaning cycle

Instructions for the User

11.6.3 Setting the cleaning cycle

Use PT2 to select one of the two pyrolysis functions (Manual background and Manual background) with the oven in ON status (see point 7.4, Function Selection).

To start the cleaning (Pyrolysis) cycle, first press knob PT1 twice to set its duration (Manual background ).

Turn knob PT1 to the right or left to increase or decrease the cycle duration between a minimum of 1h 30m and a maximum of 3h 00m. (Except for the Manual background function where the cycle duration is fixed at 1h 30m).

The message PYro will appear on DSPL 3 to indicate that cleaning is in

progress. The temperature symbol «Manual background» will come on and the degree sign «°» will flash to indicate that the internal pyrolysis temperature has not yet been reached. When the preset temperature is reached the degree symbol «°» will remain constantly on.

About 2 minutes after the cleaning (Pyrolysis) cycle starts an interlock device which prevents opening of the door will be tripped.

The Manual background symbol illuminates on dps3 to indicate that this interlock device has been activated.

To select a cleaning cycle with delayed start, after setting the duration

press PT1 once. The Manual background symbol and the current time will appear on the display.

Turning PT1 to the right increases the time, allowing the cleaning start time required to be set.

A few seconds after the required duration is set, the Manual background and Manual background symbols will stop flashing, and the oven will start to wait for the starting time set.

It is not possible to select any functions once the door interlock has been activated. Wait for the Manual background symbol to go out.