OPERATING INSTRUCTIONS
Intermittent Pilot - WHITE RODGERS 36C & 36E and Honeywell VR8304A (Natural or Propane),
VR8304P (Propane Only)
Direct Ignition - White Rodgers 36C & 36E and Honeywell VR8305A (Natural or Propane),
VR8305P (Propane Only)
1.STOP! Read the safety information above.
2.Set the thermostat to lowest setting.
3.Turn off all electric power to the appliance.
4.This appliance is equipped with an ignition device which automatically lights the pilot or burner. Do not try to light the pilot or burner by hand!
5.Remove control access panel.
6.Turn the gas control knob clockwise to the full “OFF” position, on
7.Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.
8.Turn the gas control knob
9.Replace control access panel.
10.Turn on all electric power to the appliance.
11.Set thermostat to desired setting.
12.If the appliance will not operate, follow the instructions “TO TURN OFF GAS TO APPLIANCE” and call your service technician or gas supplier.
PRESSURE REGULATOR
OUTLET PRESS. TAP
PRESSURE REGULATOR
ADJUSTMENT (UNDER
CAP SCREW)
GAS INLET
ON
OFF
OUTLET PRESS. TAP
GROUND
TERMINALS (2)
GAS OUTLET
ADJUSTMENT (UNDER
CAP SCREW)
GAS INLET
ON
OFF
GROUND TERMINALS (2)
GAS OUTLET
GAS CONTROL KNOB
| GAS CONTROL KNOB |
HONEYWELL VR8304A/P | |
| PRESS. REGULATOR |
GAS INLET | GAS OUTLET |
NO |
|
OFF |
|
GAS CONTROL KNOB | PILOT FLOW ADJ. SCR. |
SHOWN IN "OFF" POSITION |
|
WHITE RODGERS 36E
HONEYWELL VR8305M/P
PRESS. REGULATOR
GAS INLET | OF | GAS OUTLET |
F |
ON
GAS CONTROL KNOB | PILOT FLOW ADJ. SCR. | |
SHOWN IN "ON" POSITION | ||
|
WHITE RODGERS 36C
TO TURN OFF GAS TO APPLIANCE
1.Set the thermostat to lowest setting.
2.Turn off all electric power to the appliance if service is to be performed.
3.Remove control access panel.
4.Turn the gas control knob clockwise to “OFF”. On
5.Replace control access panel.