Smooth Fitness 7.35 R user manual Troubleshooting Symptom Cause Solution

Models: 7.35 R

1 39
Download 39 pages 19.27 Kb
Page 37
Image 37

 

 

 

 

www.smoothfitness.com

 

37

 

 

 

TROUBLESHOOTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYMPTOM

CAUSE

SOLUTION

 

 

No power to display

A). Not plugged in.

Please check power input and

 

 

 

 

B). Power switch not activated

fuse.

 

 

 

 

C). Power input circuit breaker

Contact your dealer if unit is

 

 

 

 

blown.

plugged in, powered on and

 

 

 

 

 

circuit breaker is depressed.

 

 

LCD display abnormal

LCD damaged

Contact your dealer for

 

 

 

 

 

troubleshooting

 

 

Show E1

A).speed feed back problem.

Switch off the power and

 

 

 

 

B).Motor console damaged.

switch on after 10 seconds

 

 

 

 

 

then press START. Check:

 

 

 

 

 

1. Does the running belt

 

 

 

 

 

move?

 

 

 

 

 

2. If the running belt moves,

 

 

 

 

 

does E1 appear after 10

 

 

 

 

 

seconds?

 

 

 

 

 

If the belt moves and E1 does

 

 

 

 

 

not appear after powering off,

 

 

 

 

 

lubricate the running belt and

 

 

 

 

 

deck. If the melt moved and E1

 

 

 

 

 

appears, please contact your

 

 

 

 

 

dealer.

 

 

Show E2(few seconds and

OTC device short circuit.

Clean the OTC device

 

 

OTC looses function)

 

certainty and reset

 

 

 

 

 

power.sensors.

 

 

Show E7

Incline motor malfunction.

You can keep going to use

 

 

 

 

 

except adjust the grade.

 

 

 

 

 

Contact your agent to

 

 

 

 

 

determine and get solutions.

 

 

Show E8

Console memory device

Contact your dealer for

 

 

 

 

damaged.

 

 

 

 

troubleshooting

 

 

 

 

 

 

 

Show E9

A).Do not hold hand pulse

Test again according the

 

 

 

 

device during Body Index test.

steps.

 

 

 

 

B). hand pulse device problem.

Contact your dealer.

 

 

 

 

 

 

 

 

 

Page 37
Image 37
Smooth Fitness 7.35 R user manual Troubleshooting Symptom Cause Solution