MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX and flexPWR® Technology in a Small Footprint

Datasheet

6.2.1.2100M MII Transmit Timing

Clock Out -

 

 

 

 

 

 

TX_CLK

 

 

 

 

 

 

 

 

 

 

 

 

T3.1

 

Data In -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valid Data

 

 

 

 

 

TXD[3:0]

 

 

 

 

 

 

 

 

 

 

 

TX_EN

 

 

 

 

 

 

TX_ER

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6.3 100M MII Transmit Timing Diagram

Table 6.3 100M MII Transmit Timing Values

PARAMETER

DESCRIPTION

MIN

TYP

MAX

UNITS

NOTES

 

 

 

 

 

 

 

T3.1

Transmit signals required setup to

12

 

 

ns

 

 

TXCLK rising

 

 

 

 

 

 

 

 

 

 

 

 

 

Transmit signals required hold

0

 

 

ns

 

 

after TXCLK rising

 

 

 

 

 

 

 

 

 

 

 

 

 

TXCLK frequency

 

25

 

MHz

 

 

 

 

 

 

 

 

 

TXCLK Duty-Cycle

 

50

 

%

 

 

 

 

 

 

 

 

SMSC LAN8710/LAN8710i

57

Revision 1.0 (04-15-09)

 

DATASHEET