Soleus Air SG-TTW-12ESEZ-26, SG-TTW-09HC-26 manual Figure B, Figure C, Power Clamp Cord, Figure D

Models: SG-TTW-09ESE-26 SG-TTW-12ESEZ-26 SG-TTW-12HC-26 SG-TTW-09HC-26

1 17
Download 17 pages 12.58 Kb
Page 6
Image 6
Figure B

Figure 3

3.Remove shipping pads inside air conditioner next to compressor. (See Figure B.)

Remove shipping pads

Figure B

4.Carefully slide the chassis into the sleeve. Ensure that the ground wire is not pinched or in the path of the condenser fan.

5.Loosen locking plate screw and rotate tab with tab behind wall case flange (See Figure C) then tighten locking plate screw.

3

Locking

Plate Figure CPower

Figure C

6.If outlet is on the left side of the unit. route power cord as shown in Figure D.

Power

Figure D Clamp Cord