SONAMP® 875D SE
875D SE Serial Commands
Serial Protocol: Baud Rate = 9600, N, 8, 1; single CR |
|
|
|
| ||
Commands In | Syntax | Parameters | State |
| ||
Power | :Pxy<cr> | x = Zone 1 | 0= Off; 1= On | |||
Zone Volume Set | :Vxyyy<cr> | x = Zone | 0 | (Off) – 100 | (Max) | |
Channel Volume Set | :VCxyyy<cr> | x = Channel 1 - 8 or G (Global), yyy = Volume 0 - 100 | 0 | (Off) – 100 | (Max) |
NOTE: Issuing a Volume Set command when the amplif ier is OFF will pre - set the zone or channel’s start - up volume to that level .
Zone Volume Incremental Step :Vxyy<cr> | x = Zone | |
Channel Volume Incremental Step: :VCxyy<cr> | x = Channel |
NOTE: The 875D SE stores independent settings for Channel and Zone Volume. If Channel Volume commands are sent to a zone that is being controlled with Zone Volume commands (and visa - versa), the volume may initially change to a dif ferent level than expected .
Zone Mute | :Mxy<cr> | x = Zone | 0 | = Mute Off; 1= Mute On | |
Channel Mute | :MCxy<cr> | x = Channel 1 - 8 or G (Global), y = State | 0 | = Mute Off; 1 = Mute On | |
BBE Signal Processing | :BPxy<cr> | x = Zone | or G (Global), y = State | 0= Off; 1= On | |
BBE HI & LO Frequency Boost | :BBxy<cr> | x = Zone | or G (Global), y = State | 0= +6dB; 1=+9dB | |
NOTE: The echo for this will provide two values (HI and LO) |
|
| |||
BBE HI Frequency Boost | :BHxy<cr> | x = Zone | or G (Global), y = State | 0= +6dB; 1=+9dB | |
BBE LO Frequency Boost | :BLxy<cr> | x = Zone | or G (Global), y = State | 0= +6dB; 1=+9dB |
Adding a
Queries | Syntax | Parameters |
| State | |
Temperature | :TP?<cr> | – |
|
| 0 – 100 Degrees C |
Audio Trigger Input | :ATIx?<cr> | x = Zone | or G (Global) [see Notes] | 0= Off; 1= On | |
Fault/Protection | :FPx?<cr> | x = Zone 1 | or G (Global) [see Notes] | 0= Normal; 1= Fault | |
Voltage Trigger Input | :VTIx?<cr> | x = Zone 1 | 0= Off; 1= On | ||
:TVLx?<cr> | x = Channel | 0 – 100 | |||
Firmware Version | :VER?<cr> | – |
|
| Version 1.03 or later |
(continued on page 16)