Self-diagnosis Code

 

 

by:

Block

Detailed

Symptom/State

Correction

Repaired

Function

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect the lens block focus reset sensor (Pin qs of CN1551 of

E

6

1

0

0

Difficult to adjust focus

VC-256 board) when focusing is performed when the control dial

(Cannot initialize focus.)

is rotated in the focus manual mode and the focus motor drive circuit

 

 

 

 

 

 

 

 

 

 

 

(IC1551 of VC-256 board) when the focusing is not performed.

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect the lens block zoom reset sensor (Pin qf of CN1551 of

E

6

1

1

0

Zoom operations fault

VC-256 board) when zooming is performed when the zoom lens is

(Cannot initialize zoom lens.)

operated and the zoom motor drive circuit (IC1551 of VC-256

 

 

 

 

 

 

 

 

 

 

 

board) when zooming is not performed.

 

 

 

 

 

 

 

 

 

 

 

 

Handshake correction function does not

Inspect pitch angular velocity sensor (SE751 of MI-041 board)

E

6

2

0

0

work well. (With pitch angular velocity

 

 

 

 

 

sensor output stopped.)

peripheral circuits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Handshake correction function does not

Inspect yaw angular velocity sensor (SE752 of MI-041 board)

E

6

2

0

1

work well. (With yaw angular velocity

 

 

 

 

 

sensor output stopped.)

peripheral circuits.

 

 

 

 

 

 

 

 

 

 

 

 

 

— 7 —