4. |
|
| |||||
|
| ||||||
|
|
|
|
|
|
| |
by: | Block | Detailed | Symptom/State | Correction | |||
Repaired | |||||||
Function | Code |
|
| ||||
|
|
| |||||
|
|
|
|
|
|
| |
C | 0 | 4 | 0 | 0 | Use the InfoLITHIUM battery. | ||
|
|
|
|
|
|
| |
C | 2 | 1 | 0 | 0 | Condensation. | Remove the cassette, and insert it again after one hour. | |
|
|
|
|
|
|
| |
C | 2 | 2 | 0 | 0 | Video head is dirty. | Clean with the optional cleaning cassette. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 1 | 0 | LOAD direction. Loading does not | Load the tape again, and perform operations from the beginning. | |
complete within specified time | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
C | 3 | 1 | 1 | 1 | UNLOAD direction. Loading does not | Load the tape again, and perform operations from the beginning. | |
complete within specified time | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
C | 3 | 1 | 2 | 0 | T reel side tape slacking when unloading. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 2 | 1 | S reel side tape slacking when unloading. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 2 | 2 | T reel fault. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 2 | 3 | S reel fault. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 3 | 0 | FG fault when starting capstan. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 3 | 1 | FG fault during normal capstan operations. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 4 | 0 | FG fault when starting drum. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 4 | 1 | PG fault when starting drum. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 4 | 2 | FG fault during normal drum operations. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 4 | 3 | PG fault during normal drum operations. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 1 | 4 | 4 | Phase fault during normal drum operations. | Load the tape again, and perform operations from the beginning. | |
|
|
|
|
|
|
| |
C | 3 | 2 | 1 | 0 | LOAD direction loading motor time- | Remove the battery or power cable, connect, and perform | |
out. | operations from the beginning. | ||||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
C | 3 | 2 | 1 | 1 | UNLOAD direction loading motor | Remove the battery or power cable, connect, and perform | |
operations from the beginning. | |||||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
C | 3 | 2 | 2 | 0 | T reel side tape slacking when | Remove the battery or power cable, connect, and perform | |
unloading. | operations from the beginning. | ||||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
C | 3 | 2 | 2 | 1 | S reel side tape slacking when | Remove the battery or power cable, connect, and perform | |
unloading. | operations from the beginning. | ||||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
C | 3 | 2 | 2 | 2 | T reel fault. | Remove the battery or power cable, connect, and perform | |
operations from the beginning. | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
C | 3 | 2 | 2 | 3 | S reel fault. | Remove the battery or power cable, connect, and perform | |
operations from the beginning. | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
C | 3 | 2 | 3 | 0 | FG fault when starting capstan. | Remove the battery or power cable, connect, and perform | |
operations from the beginning. | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
C | 3 | 2 | 3 | 1 | FG fault during normal capstan | Remove the battery or power cable, connect, and perform | |
operations. | operations from the beginning. | ||||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
C | 3 | 2 | 4 | 0 | FG fault when starting drum. | Remove the battery or power cable, connect, and perform | |
operations from the beginning. | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
C | 3 | 2 | 4 | 1 | PG fault when starting drum. | Remove the battery or power cable, connect, and perform | |
operations from the beginning. | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
C | 3 | 2 | 4 | 2 | FG fault during normal drum | Remove the battery or power cable, connect, and perform | |
operations. | operations from the beginning. | ||||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
C | 3 | 2 | 4 | 3 | PG fault during normal drum | Remove the battery or power cable, connect, and perform | |
operations. | operations from the beginning. | ||||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
C | 3 | 2 | 4 | 4 | Phase fault during normal drum | Remove the battery or power cable, connect, and perform | |
operations. | operations from the beginning. | ||||||
|
|
|
|
| |||
|
|
|
|
|
|
|
— 6 —