5-36 ROUTING SWITCHER SYSTEM (E)
5-2. Setting Items of the Secondary Station
1234
OUT1
OUT2
OUT3
OUT17
OUT18
OUT19
IN
Level1Level1
IN
5678
Expansion input
Switcher A Switcher B
R: SET ROUTE (BKS-R1607/R1608/R3209/R3210/R3216/R1617/R1618/R3219/R3220/R1621)
Purpose
This is the function to display the source names that are
expanded by combining the two switchers for the purpose
of expanding numbers of input.
When a route is set, the source that is connected to the
route destination, is automatically chased out the and the
name of the source is displayed. In an example shown
below, IN001 of the switcher A is displayed as the source
name when OUT017 of the switcher B is selected.
It has another function as follows. When a request of
switching including the expanded destination, is issued,
crosspoint of the route destination side is automatically
switched. For example, when IN001-OUT001 of the
switcher A is switched, IN005-OUT017 of the switcher B
is also switched at the same time.
Route Function
Setting procedure
1. Select the menu item [R] of the secondary station.
2. Select the desired item using the cursor key.
3. Pressing [Enter] establishes the route setting mode.
When [Enter] is pressed again before entering data,
registration is canceled.
4. Enter the “Type + No.” name or description name.
(The setting methods remains the same as that of
phantom. Refer to the description of the secondary
station’s menu item [H : SET PHANTOM TABLE].
However, the destination name of the switcher-A to
which source of the switcher-B is connected, should be
input on this menu, instead of the phantom name.)
5. Press [Enter] to confirm the input contents.
6. Pressing [Ctrl] _ [E] switches to the menu screen of
the secondary station.
Pressing [Ctrl] _ [D] returns to the menu screen of the
primary station.
SONY ROUTING SYSTEM SETUP MENU BKS-R3216 V1.00 STATION NUMBER 4
SET ROUTE(ROUTE DESTINATION:DESTINATION<SOURCE-LEVEL)
ROUTE | DEST | SOURCE | LEVEL1-8 | ROUTE | DEST | SOURCE | LEVEL1-8
OUT001 : OUT017 < IN005 - 10000000 | OUT002 : OUT018 < IN006 - 10000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
....... : ....... < ....... - 00000000 | ....... : ....... < ....... - 00000000
0=IN 1=OUT 2=SONY 3=VTR 4=SUP 5=CB 6=AIR 7=ME
8=PGM 9=CL A=SL B=L C=RET D=MIX E=JEEP F=OSC
G=L/A H=REM I=CAM J=STDO K=AUX L=COV M=BS N=CS
O=SAT P=CG Q=WETH R=TEST S=HD T=D1- U=D2- V=SEG
Ctrl-E:MENU Ctrl-D:RETURN Ctrl-N:DESCRIP.NAME +:DST+
Example of Setting Screen
In the setting screen example as shown above, the cross-
point of IN005-OUT017 is switched at the same time when
a crosspoints including OUT001 (ex. IN002-OUT001) is
switched. Then, source (IN002) of the switcher-A’s
OUT001 is displayed (IN002-OUT017) for OUT017 of the
switcher-B. The above described operation is executed by
selecting OUT001 and IN002 from the remote control unit.
However, it is recommended to set the phantom of IN002:
OUT001 < IN002 beforehand on the remote control panel,
because the operation of selecting IN002-OUT001 instead
of OUT017 looks unnatural when IN002-OUT017 is going
to be taken.
To add the offset amount to the selected destination, enter
[+] in the DEST column before pressing [Enter].
After “DEST +” is displayed, enter the offset value (0 to
1023) and press [Enter] to store the value.
Each level can be set by selecting ON (1) or OFF (0).