5-11
ROUTING SWITCHER SYSTEM (E)
5-1. Setting Items of the Primary Station
K: RESET TO DEFAULT TABLE
K: DEFAULT TABLE
Purpose
This menu is used to initialize the table data. Do not
perform this menu when modifying the table data.
Setting Procedure
1. Select menu item [K]. The message “RESET TO
DEFAULT TABLE? (y/n)” will be displayed at the
bottom of the screen.
2. Initialization is performed when [Y] is pressed. To
cancel initializing, press [N].
n
The table data will be lost when performing the menu item
[K].
L: SET PHYSICAL ASSIGNMENT
Purpose
Assign the physical numbers of the switcher to the destina-
tion numbers, source numbers and the levels of the virtual
matrix.
Do not assign the same number.
Setting Procedure
1. Select menu item [L].
2. Each time [F5] is pressed, the setting screen will
change as follows.
Source number setting screen destination number
setting screen source number setting screen.
..
..
.Source Number Setting Procedure
3. Select the source number setting screen.
4. Select the physical number and the level using the
cursor, and assign them to desired source number and
level on the virtual matrix. When [Enter] is pressed,
the physical assignment can be typed.
5. Enter the physical number using numerical keys, and
press [Enter].
6. Next, enter the physical level, and press [Enter] to set
it.
If press [Ctrl] _ [F] before setting, the physical
number and level will be returned to the previous
values.
If the physical number and physical level to be set has
been already used, cancel their settings first before
setting new ones.
To cancel, select the physical number and level to be
canceled, and press [Ctrl] _ [P].