5-4 ROUTING SWITCHER SYSTEM (E)
5-1. Setting Items of the Primary Station
SOURCE NUMBER TRANSCODE DVS-V6464B V2.10 STATION NUMBER 1
001=VTR001 002=VTR002 003=VTR003 004=VTR004 
005=VTR005 006=VTR006 007=VCR101 008=VCR102 S 
009=AUX001 S 010=AUX002 011=CAM001 S 012=CAM002 
013=CG001 014=NETA001 015=SS001 016=BARS001 
017=....... 018=....... 019=....... 020=....... 
021=....... 022=....... 023=....... 024=....... 
025=....... 026=....... 027=....... 028=....... 
029=....... 030=....... 031=....... 032=.......
033=....... 034=....... 035=....... 036=....... 
0=VTR 1=VCR 2=AUX 3=FLM 4=TEST 5=STU 6=CAM 7=REM
8=CG 9=NETA A=ENG B=ED C=FS D=SS E=BARS F=PHAN 
F1:SEARCH F2:JUMP F3:PgUp F4:PgDn S:SECRET Ctrl-E:RETURN TO MENU
D: SET SOURCE NAME
Purpose
This menu is used to set the source name and secret
function (inhibition of source selection with a remote
control unit).
A number between 001 to 999 and a type name set at the
menu item [B : SET SOURCE/DEST TYPE] can be set to
each source name. Description name can be set by
changing the name mode at menu item [J : NAME
STYLE] in the menu. For details of setting the name,
refer to [J] in the menu.
The secret function is necessary when a source signal
should not be taken. When secret is set, remote control
units cannot select the source signal.
Setting Procedure (Source Name)
1. Select menu item [D].
2. Press the cursor keys or the function keys, to select the
source number.
3. When [Ctrl] _ [P] is pressed, the source name will be
deleted.
4. When [Enter] is pressed, the source name can be
typed. If [Enter] is pressed before entering a name,
the registration will be deleted and the cursor moves to
the next position.
5. Select the code assigned to each type name, and use
the numerical keys to enter the source name.
6. When [Enter] is pressed, the source name will be set
and the cursor moves to the next position.
If [Ctrl] _ [F] is pressed before the setting, the
original source name will be returned.
7. When [Ctrl] _ [E] is pressed, the menu screen will be
displayed.
n
1. The same name cannot be given to assigned to two or
more sources. If this is done, an error message will be
displayed at the bottom of the screen.
Example: “VTR001 is used already; Ignored”
source name
2. When the Description name is selected at menu item
[J], the screen will display the Description name in
addition to the “Type + Number” name.
In this menu, the Description name is used for settings.
Setting Procedure (Secret Function)
1. Select the source name using the cursor, and press [S].
“S” is displayed after the source name, and the secret
is set. Secret cannot be set for a number whose source
name has not been assigned.
2. To release the secret function, select the source name
and press [S] once again.
When the password is required, input the password
and press [Enter]. The secret will be released.
n
For details on password settings, refer to the menu item [P
: CHANGE PASSWORD].
Example of Setting Screen