5-24 ROUTING SWITCHER SYSTEM (E)
5-1. Setting Items of the Primary Station
DISPLAY TABLE DATA DVS-V6464B V2.10 STATION NUMBER 1
0000:49 4E 00 00 00 00 00 00 4F 55 54 00 00 00 00 00 : IN......OUT.....
0010:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 : ................
0020:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 : ................
0030:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 : ................
0040:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 : ................
0050:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 : ................
0060:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 : ................
0070:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 : ................
0080:56 49 44 00 00 00 00 00 41 31 00 00 00 00 00 00 : VID.....A1......
0090:41 32 00 00 00 00 00 00 34 00 00 00 00 00 00 00 : A2......4.......
00A0:35 00 00 00 00 00 00 00 36 00 00 00 00 00 00 00 : 5.......6.......
00B0:37 00 00 00 00 00 00 00 38 00 00 00 00 00 00 00 : 7.......8.......
00C0:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 : ................
00D0:00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 : ................
00E0:00 00 00 00 00 00 00 00 00 02 FF FF 10 00 00 02 : ................
Ctrl-E:RETURN TO MENUÅ
SET UNIT DETECTABLE DVS-V6464B V2.10 STATION NUMBER 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
+ 
001-020 M ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?
021-040 ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?
041-060 ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?
061-080 ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ?
081-100 
101-120 
121-140 
141-160 
161-180 
181-200 
201-220 
221-240 
241-254 * * * * * *
01:DVS-V1616 02:DVS-V3232 03:DVS-A3232 04:BKS-R1601 05:BKS-R3202 
06:BKS-R3203 07:BKS-R3281 08:DVS-V6464 09:BKS-R5000 10:DVS-RS1616 
11:DVS-TC3232 12:BKDM-5080 13:BKS-R3204 14:BKS-R3205 15:BKS-R3206 
16:BKS-R3280 17:BZR-1000 18:DVS-V3232B 19:DVS-V6464B
Ctrl-E:RETURN TO MENU
Y: DISPLAY TABLE (Except for HDS-V3232)
Purpose
This menu is used to display the table data set with the
control terminal.
Operation Procedure
1. Select menu item [Y]. The following message will be
displayed at the bottom of the screen.
Display : “DISPLAY TABLE DATA? (y/a/n)”
2. Press [E], and the signal format (4: 2: 2/4 fsc) set for
each input/output will be displayed in hexadecimal.
(DVS-V* * * * series only.)
Press [A], and all table data will be displayed in
hexadecimal.
When [N] is pressed, the table data display will be
canceled.
3. If [SPACE] is pressed during the display, the display
will be interrupted. When [SPACE] is pressed once
again, the display will begin.
4. Press [Ctrl] _ [E] to stop the display. The menu
screen will be displayed.
Example of Display
n
For the contents of the table data, refer to the S-BUS
Protocol Manual.
Z: SET UNIT DETECTABLE
Purpose
This menu is used to check the possibility of communica-
tion of secondary stations connected to the S-BUS data
link periodically.
During checking, “?” appears. After the completion of
checking, the code number indicating the type of each
device appears.
If the secondary station does not communicate for a given
period, the message below appears.
“STATION **
**
* **
**
* **
**
* FAILURE (DISCONNECT OR POWER DOWN)”
Station number
Setting Procedure
1. Select the menu item [Z].
2. Select a secondary station you want to check using the
cursor.
3. Press [Enter], and “?” appears.
To cancel “?”, press [Enter] again.
4. Press [Ctrl] _ [E], and the display is changed to the
menu screen to begin checking.
5. After about ten seconds, select the menu item [Z]. If
the secondary station is available for communication,
“?” changes to a device code number.
n
A secondary station to be checked should be set available
for communication in advance at menu item [F : SET
ACTIVE UNIT NUMBER]
Example of Setting Screen