5-55
ROUTING SWITCHER SYSTEM (E)
5-7. Initialization of Table Data
5-7. Initialization of Table DataThere are five ways of initializing the table data. Note that the way to be used depends on which item is
initialized.
5-7-1. Initializing Procedure and Corresponding Items
DVS-V3232B/V6464B :
Initializing Procedure Corresponding Menu Items
1 1.Set the test switch (S3) on the CPU-149 board to “D”. All items of the primary and secondary stations.
2.Press the reset switch (S5).
2 1.Set the test switch (S3) on the CPU-149 board to “C”. [W : SYSTEM STATUS LOG]
2.Press the reset switch (S5).
3 Select the menu item [K : RESET TO DEFAULT TABLE] All items of the primary station excluding the
of the primary station and press [Y]. following 4 items.
.[H : SET GLOBAL PHANTOM]
.[N : SET DESCRIPTION NAME GROUP]
.[O : SET TIE LINES]
.[W: SYSTEM STATUS LOG]
4 Select the menu item [K : reset To default table] All items of the secondary station excluding
of the secondary station and press [Y]. the crosspoint data.
5 Select the menu item [U : SELECT REMOTE PROTOCOL] [U : SELECT REMOTE PROTOCOL]
of the secondary station and press [F2] (DEFAULT).
BKPF-R70 :
Initializing Procedure Corresponding Menu Items
1 1.Set the test switch (S5) on the CPU-256 board to “D”. All items of the primary and secondary stations.
2.Press the reset switch (S1).
2 1.Set the test switch (S5) on the CPU-256 board to “C”. [W : SYSTEM STATUS LOG]
2.Press the reset switch (S1).
3 Select the menu item [K : RESET TO DEFAULT TABLE] All items of the primary station excluding the
of the primary station and press [Y]. following 4 items.
.[H : SET GLOBAL PHANTOM]
.[N : SET DESCRIPTION NAME GROUP]
.[O : SET TIE LINES]
.[W: SYSTEM STATUS LOG]
4 Select the menu item [K : reset To default table] All items of the secondary station excluding
of the secondary station and press [Y]. the crosspoint data.
5 Select the menu item [U : SELECT REMOTE PROTOCOL] [U : SELECT REMOTE PROTOCOL]
of the secondary station and press [F2] (DEFAULT).