GDM-F500/F500T9

Connect the communication cable of the computer to the connector located on the D board or US board on the monitor. Run the service software and then follow the instruction.

1 1-690-391-21 2

A-1500-819-A

3 3-702-691-01

 

 

 

Interface Unit

 

Connector Attachment

 

IBM AT Computer

 

 

 

 

To BUS CONNECTOR

or

as a Jig

 

 

 

 

 

 

 

 

 

 

D-sub

mini Din

4 Pin

4 Pin 4 Pin

 

(9 Pin [female])

(8Pin)

 

 

 

 

 

*The parts above ( 1 3 ) are necessary for DAS adjustment.

Convergence Rough Adjustment

(1)Receive an image of the white crosshatch signals (white lines on black).

(2)Place the protrusions of the 6-fold poles magnet attached to the CRT neck upon each other. (Fig. 1)

(3)Make rough adjustment of the H and V direction conver- gence by using 4-fold poles magnet.

Convergence Specification

B

 

Bezel opening

 

 

 

A Picture

C

fH

60kHz

60kHz

 

 

 

A Zone

0.24 mm

0.24 mm

 

 

 

B Zone

0.28 mm

0.32 mm

 

 

 

C Zone

0.32 mm

0.36 mm

 

 

 

 

 

TLH correction plate (Put in one side only)

Protrusions

YBH

XBV

XCV

YCH

Fig. 1

APH

TLV

 

 

 

*

60°

 

 

Fig. 3

 

Fig. 2

 

* Set so that the protruding parts of the 2 magnet rings agree with each other.

White Balance Adjustment Specification

1.9300K

x=0.283 ± 0.005 y=0.298 ± 0.005

(All White)

2.6500K

x=0.313 ± 0.005 y=0.329 ± 0.005

(All White)

3.5000K

x=0.346 ± 0.005 y=0.359 ± 0.005

(All White)

Vertical and Horizontal Position and Size Specification

XCV

B

R

TLV

R

B

B

R

XBV

TLH

R

B

R B B R

YCH

YBH

R

B

R

B

A

 

 

 

 

b

 

 

 

 

b

 

MODE

1, 2, 4, 5

3

B

 

 

 

 

A

388 mm

364 mm

a

a

B

291 mm

291 mm

 

 

a

3.2 mm

 

 

 

b

3.2 mm

 

 

 

Focus adjustment

Adjust the focus volume 1 and 2 for the optimum focus.

HDK

Focus 2

Focus 1

4-2

Page 22
Image 22
Sony GDM-F500T9 service manual ∙ Convergence Rough Adjustment, Mode