Tips
•When Auto Calibration starts:–Stand some distance from the speakers and the listening position to avoid measurement failure. This is because test signals are output from the speakers during measurement.
–Avoid making noise to get a more accurate measurement.•The Auto Calibration function will be canceled when you do the following during the measurement process:
–Press ?/1 or MUTING.–Press input buttons on the remote or INPUT SELECTOR on the receiver.–Change the volume level.–Press AUTO CAL again.Confirming/saving the measurement results1 Confirm the measurement result.When the measurement ends, a beep sounds and the measurement result appears on the display.
Measurement Display | Explanation | |
result |
|
|
|
|
|
When the | SAVE | Proceed to step |
measurement |
| 2. |
process |
|
|
completes |
|
|
properly |
|
|
|
|
|
When the | ERROR | See “When |
measurement | XXXX | error codes |
process fails |
| appear” (page |
|
| 28). |
|
|
|
Item | Explanation |
RETRY | Performs the Auto |
| Calibration again. |
|
|
SAVE | Saves the measurement |
| results and exits the setting |
| process. |
|
|
WARN CHK | Displays warning |
| concerning the |
| measurement results. See |
| |
| CHK”” (page 29). |
|
|
PHASE | Displays the phase of each |
| speaker (in phase/out of |
| phase). See “When you |
| |
|
|
DISTANCE | Displays the measurement |
| result for speaker distance. |
|
|
LEVEL | Displays the measurement |
| result for speaker level. |
|
|
EXIT | Exits the setting process |
| without saving the |
| measurement results. |
When error codes appear
Try the remedies and perform the Auto Calibration again.Error code Cause and remediesERROR 32 None of the speakers were detected. Make sure that the optimizer microphone is connected properly and perform the Auto Calibration again.
If the optimizer microphone is connected properly but the error code appears, the optimizer microphone cable may be damaged or improperly connected.
ERROR F 33 • None of the front speakers are connected or only one front speaker is connected.
•The optimizer microphone is not connected.