MANUAL SERVO

ZOOM

Adjusting the flange focal length automatically

1Set the ND filter B to 1 to adjust brightness so that the proper video light level is obtained.

2Place the flange focal length adjustment test chart A about 2-3 meters (7-10 feet) away. Zoom in and set your camcorder to locate the center of the chart in the center of the screen.

3Set the ZOOM switch F to SERVO.4Select [AUTO ADJUST] in [FLANGEBACK] of the (CAMERA SET) menu (p. 76).5Select [YES] with the SEL/PUSH EXEC dial E.

The flange focal length adjustment starts and [EXECUTING] appears on the screen. When the adjustment is completed, [Completed.] appears on the screen.

If the adjustment fails, [Could not adjust.] appears on the screen. Try the adjustment again.

Adjusting the flange focal length manually1Perform steps 1 and 2 of “Adjusting the flange focal length automatically.”2Set the ZOOM switch F to MANUAL.3Select [MANU ADJUST] in [FLANGEBACK] of the (CAMERA SET) menu.
4Select [YES] with the SEL/PUSH EXEC dial E.5Turn the zoom ring D to the telephoto position.6Turn the focus ring C until the subjectcomes in focus, then press the SEL/ PUSH EXEC dial E.7Turn the zoom ring D to the wide angle position.8Turn the focus ring C until the subject

comes in focus, then press the SEL/ PUSH EXEC dial E.

When the adjustment is completed, [Completed.] appears on the screen.

If the adjustment fails, [Could not adjust.] appears on the screen. Try the adjustment again.

zTips

You can check the focusing easily if you do the following before adjusting the focal length.

Set [PEAKING] in the (DISPLAY SET) menu to [ON] (p. 79).

Press the ASSIGN button to which [EXP.FOCUS] is assigned (L2 button by default) (p. 43).

Started Getting

Continued , 11