Self-Diagnostic Screen Display

For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confi rmed, it is possible to bring up past occurrences of failure on the screen for confirmation.

To Bring Up Screen Test

In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below:

Display Channel

5 Sound Volume

- Power ON

Note that this differs from entering the Service Mode (Sound Volume

+

).

Self-Diagnostic Screen Display

SELF DIAGNOSTIC

2:000

3:N/A

4:000

5:001

101:N/A

Numeral “0” means that no fault was detected. Numeral “1” means a fault was detected one time only.

Handling of Self-Diagnostic Screen Display

Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during repairs. When you have completed the repairs, clear the result display to “0”.

Unless the result display is cleared to “0”, the self-diagnostic function will not be able to detect subsequent faults after completion of the repairs.

Clearing the Result Display

To clear the result display to “0”, press buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as shown below:

Channel

8 ENTER

Quitting the Self-Diagnostic Screen

To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.

Self-Diagnostic Circuit

 

 

 

 

IC301

 

 

 

Y/CHROMA JUNGLE

FROM

 

 

 

 

 

 

 

 

CRT

 

21 IK IN

 

 

 

FROM

 

18 HP/PROTECT

 

IC521

 

 

 

 

 

 

PIN 7

 

 

SDA 35

 

 

 

 

 

 

IC541

IC001

 

IC003

V. OUT

SYSTEM

 

MEMORY

 

IO-BDAT

36

5 BDA

REF 3

17 I-PROT

 

 

 

O-LED

18

 

 

37

 

DISPLAY

 

IO-SDAT

 

 

 

 

+B overcurrent (OCP)

Occurs when an overcurrent on the +B (115V) line is detected by pin 18 of IC301. If the voltage of pin 18 of IC301 is less than 1V when V.SYNC is more than seven verticals in a period, the unit will automatically turn off.

Vertical Deflection Stopped

Occurs when an absence of the vertical defl ection pulse is detected by pin 17 of IC001. Power supply will shut down when waveform interval exceeds 2 seconds.

White Balance Failure

If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be detected by IC301. TV will stay on, but there will be no picture.

*(Refers to the RGB levels of the AKB detection Ref pulse that detects 1K).