FE-2 SELF DIAGNOSTIC SOFTWARE

The identification of errors within the FE-2 chassis is triggered in one of two ways :- 1: Busy or 2: Device failure to respond to IIC. In the event of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with a continuous flashing LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant device number will be displayed through the LED (Series of flashes which must be counted) See table 1., non fatal errors are reported using this method.

Each time the software detects an error it is stored within the NVM. See Table 2.

Table 1

Error Message

LED

Code

 

No error

00

Reserved

01

OCP ( Over Current Protection )

02

Not Used

03

No Vertical Sync

04

IKR Error at power on

05

IIC bus clock and/or data lines low at power on

06

NVM no IIC bus acknowledge at power on

07

Not Used

08

Tuner no acknowledge at power on

09

 

 

Sound Processor Error

10

 

 

Jungle controller 8 volts error

11

 

 

Flash Timing Example : e.g. error number 3

StBy LED

ON

ON

ON

 

OFF

OFF

How to enter into Table 2

1.Turn on the main power switch of the TV set and enter into the

‘Stanby Mode’.

2.Press the following sequence of buttons on the Remote Commander.

i+

5

-

 

(ON SCREEN

(DIGIT 5)

(VOLUME -)

(TV)

DISPLAY)

 

 

 

3.The following table will be displayed indicating the error count.

Table 2

ERROR MENU

 

 

 

E02

OCP

(0, 255)

0

E03

OVP N/A

(0, 255)

0

E04

VSYNC

(0, 255)

0

E05

IKR

(0, 255)

0

E06

IIC

(0, 255)

0

E07

NVM

(0, 255)

0

E08

JUNGLE

(0, 255)

0

E09

TUNER

(0, 255)

0

E10

SOUNDP

(0, 255)

0

E11

8V

(0, 255)

0

WORKING TIME

 

 

 

HOURS

 

 

2

MINUTES

 

 

11

 

 

 

 

Note: To clear the error count data press ‘80’ on the Remote commander.

6

Page 6
Image 6
Sony KV-29LS30E service manual Flash Timing Example e.g. error number, How to enter into Table