USRobotics x2/56K, 33600 user manual Reg Default Function

Models: 33600 x2/56K

1 76
Download 76 pages 22 Kb
Page 54
Image 54

Reg Default

Function

S15

0

Bit-mapped register. To set the register see

 

 

the instructions for S13.

 

 

Bit

Value

Result

 

 

0 (zero)1

Disable ARQ/MNP for V.22.

 

 

1

2

Disable ARQ/MNP for .22bis.

 

 

2

4

Disable ARQ/MNP for

 

 

 

 

V.32/V.32bis/V.32terbo.

 

 

3

8

Disable MNP handshake.

 

 

4

16

Disable MNP level 4.

 

 

5

32

Disable MNP level 3.

 

 

6

64

MNP incompatibility.

 

 

7

136

Disable V.42 detection phase.

S16

0

Bit-mapped test register. Allowable value is

 

 

2.

 

 

Bit Value Result

0Reserved.

12 Touch tone dialing test.

2–7 Reserved.

S17

0

Reserved.

S18

0

Test timer for &Tn loopback testing. Sets the

 

 

time in seconds of testing before the modem

 

 

automatically times out and terminates the

 

 

test. When set to 0, the timer is disabled.

S19

0

Sets the duration, in minutes, for the Inac-

 

 

tivity Timer. The timer activates when there is

 

 

no data activity on the phone line; at timeout

 

 

the modem hangs up. S19 = 0 disables the

 

 

timer.

S20

0

Reserved.

S21

10

Sets the length, in 10-millisecond units, of

 

 

breaks sent from the modem to the compu-

 

 

ter; applies to ARQ mode only.

S22

17

Stores the ASCII decimal code for the XON

 

 

character. Valid range is 0–127.

50 Sportster Winmodem 33600 & x2/56K - User's manual