&Zn=s Writes phone number string s to NVRAM at position n (n = 03).

&Zn=L Writes last executed dial string to NVRAM at position n (n = 03).

&Zn? Displays the phone number stored at position

n(n = 03).

&ZL? Displays the last executed dial string.

S-Registers

Default values are appropriate for most users. The settings are modified with the ATSr=n command, where r is the number of the S register and n is a decimal value between 0 and 255 (unless otherwise stated).

Use ATSr? to examine the configuration of a register. For example:

$76￿"￿(QWHU

Reg

Default

Function

 

 

 

S0

0

Sets the number of rings on which to answer

 

 

in Auto Answer Mode. When set to 0, Auto

 

 

Answer is disabled.

S1

0

Counts and stores the number of rings from

 

 

an incoming call. (S0 must be greater than

 

 

0).

S2

43

Stores the ASCII decimal code for the es-

 

 

cape code character. Default character is +.

 

 

A value of 128 – 255 disables the escape

 

 

code. The range of acceptable values is

 

 

country-dependent.

S3

13

Stores the ASCII code for the Carriage

 

 

Return character. Valid range is 0–127.

S4

10

Stores the ASCII decimal code for the Line

 

 

Feed character. Valid range is 0–127.

S5

8

Stores the ASCII decimal code for the Back-

 

 

space character. A value of 128255 disables

 

 

the Backspace key’s delete function.