Reg | Default | Function |
S13 | 0 | |
|
| want on and set S13 to the total of the val- |
|
| ues in the Value column. For example, |
|
| ATS13 = 17 enables bit 0 (value is 1) and bit |
|
| 4 (value is 16). |
Bit Value Result
01 Reset when DTR drops.
12 Reset
24 Set backspace key to delete.
38 On DTR signal, auto dial the number stored in NVRAM at position 0.
416 At power on/reset, Auto Dial the number stored in NVRAM at position 0.
532 Reserved.
664 Reserved.
7128 Disconnect on escape code.
♦♦The
This is also very helpful in situations when a remote modem/ printer application is losing characters.
S14 | 0 | |
|
| value is 1. |
Bit Value Result
01 The modem hangs up on receipt of +++, returns to command mode, and sends the NO CARRIER result code.
Sportster Winmodem 33600 & x2/56K - User's manual 49