Reg

Default

Function

S13

0

Bit-mapped register. Select the bit(s) you

 

 

want on and set S13 to the total of the val-

 

 

ues in the Value column. For example,

 

 

ATS13 = 17 enables bit 0 (value is 1) and bit

 

 

4 (value is 16).

Bit Value Result

01 Reset when DTR drops.

12 Reset non-MNP transmit buffer from 1.5K to 128 bytes.♦♦

24 Set backspace key to delete.

38 On DTR signal, auto dial the number stored in NVRAM at position 0.

416 At power on/reset, Auto Dial the number stored in NVRAM at position 0.

532 Reserved.

664 Reserved.

7128 Disconnect on escape code.

♦♦The 128-byte option lets remote users with slower modems keep data you’re sending from scrolling off their screens. When remote users send your computer an XOFF (Ctrl-S) and you stop transmitting, the data in transit from your modem’s buffer doesn’t exceed the size of their screen.

This is also very helpful in situations when a remote modem/ printer application is losing characters.

S14

0

Bit-mapped register. Allowable non-default

 

 

value is 1.

Bit Value Result

01 The modem hangs up on receipt of +++, returns to command mode, and sends the NO CARRIER result code.

1–7 Reserved.

Sportster Winmodem 33600 & x2/56K - User's manual 49