| (1) Power ON, current probe method: |
| 18.3 A (100 V), 37.1 A (240V) |
| (2) Hot switching inrush current, |
| measured in accordance with |
| European standard |
| 35.5 A (230 V) |
| |
| (1) Power ON, current probe method: |
| 21.8 A (100 V), 40.6 A (240V) |
| (2) Hot switching inrush current, |
| measured in accordance with |
| European standard |
| 38.8 A (230 V) |
Dimensions | |
| × 269.9 mm (including the |
| projection parts) |
| (20 1/2 × 18 1/2 ×10 3/4 inches) |
| (w/h/d) |
| |
| × 269.9 mm (including the |
| projection parts) |
| (23 3/4 × 19 5/8 × 10 3/4 inches) |
| (w/h/d) |
Mass | |
| 4 oz) (when no input adaptor is |
| installed) |
| Approx. 10.5 kg (23 lb 2 oz) (when two |
| |
| |
| 4 oz) (when no input adaptor is |
| installed) |
| Approx. 11.4 kg (25 lb 2 oz) (when two |
|
Operating conditions
Temperature0 °C to 35 °C (32 °F to 95 °F) Recommended temperature
| 20 °C to 30 °C (68 °F to 86 °F) |
Humidity | 30 % to 85 % (no condensation) |
Pressure | 700 hPa to 1060 hPa |
Storage and transport conditions
Humidity | 0 % to 90 % |
Pressure | 700 hPa to 1060 hPa |
Accessories supplied
AC power cord (1) AC plug holder (1) Operating Instructions (1)
Warranty Card (1)
Using the
SDI 4:2:2 input adaptor
NTSC/PAL input adaptor
Analog component input adaptor
Mounting bracket
Design and specifications are subject to change without notice.
Note
Always verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR REIMBURSEMENT ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF THIS UNIT, EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIRATION OF THE WARRANTY, OR FOR ANY OTHER REASON WHATSOEVER.
Pin assignment
1 8
PARALLEL REMOTE connector
Modular connector
Pin number | Functions |
1 | Designating composite input signal |
|
|
2 | Designating component input signal |
|
|
3 | Setting tally lamp green ON/OFF |
|
|
4 | Setting tally lamp red ON/OFF |
|
|
5 | GND |
|
|
6 | Selecting external sync. |
|
|
7 | Selecting over scan |
|
|
8 | Selecting normal scan |
|
|
You can allocate functions using the REMOTE menu (see page 29).
Wiring required to use the Remote Control Connect the function you want to use with a Remote Control to the Ground (Pin 5).
SERIAL REMOTE
51
9 6
Pin number | Signal |
1NC
Specifications 33