Sony MDS-JB920 Section Servicing Notes, Table Of Contents, Diagrams, General, Disassembly

Models: MDS-JB920

1 72
Download 72 pages 46.67 Kb
Page 4
Image 4
TABLE OF CONTENTS

 

TABLE OF CONTENTS

 

1.

SERVICING NOTES

4

2.

GENERAL

11

3.

DISASSEMBLY

14

4.

TEST MODE

18

5.

ELECTRICAL ADJUSTMENTS

23

6.DIAGRAMS

6-1. IC Pin Function Description

32

6-2.

Block Diagram – SERVO Section

41

6-3.

Block Diagram – MAIN Section

43

6-4.

Note for Printed Wiring Boards and

 

 

Schematic Diagrams

46

6-5.

Printed Wiring Board – BD Section

47

6-6.

Schematic Diagram – BD Section (1/2)

49

6-7.

Schematic Diagram – BD Section (2/2)–

51

6-8.

Schematic Diagram – MAIN Section (1/3)–

55

6-9.

Schematic Diagram – MAIN Section (2/3)–

57

6-10. Schematic Diagram – MAIN Section (3/3)–

59

6-11.

Printed Wiring Board

 

 

– MAIN Board (Side A)

61

6-12.

Printed Wiring Boards

 

 

– MAIN Board (Side B), AC/BAT Boards

63

6-13.

Printed Wiring Boards

 

 

– PANEL Section

65

6-14. Schematic Diagram – PANEL Section

67

6-15.

Schematic Diagram

 

 

– BD SWITCH Section

69

6-16.

Printed Wiring Board

 

 

– BD SWITCH Section

69

7.

EXPLODED VIEWS

75

8.

ELECTRICAL PARTS LIST

79

SECTION 1

SERVICING NOTES

SAFETY CHECK-OUT

After correcting the original service problem, perform the follow- ing safety check before releasing the set to the customer:

Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below.

LEAKAGE TEST

The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microampers.). Leakage current can be measured by any one of three methods.

1.A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers’ instructions to use these instruments.

2.A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job.

3.Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The “limit” indica- tion is 0.75 V, so analog meters must have an accurate low- voltage scale. The Simpson 250 and Sanwa SH-63Trd are ex- amples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2 V AC range are suit- able. (See Fig. A)

To Exposed Metal

Parts on Set

0.15 F

 

 

 

1.5 k Ω

AC

 

 

 

voltmeter

 

 

 

 

 

(0.75 V)

 

 

 

 

 

 

Earth Ground

Fig. A. Using an AC voltmeter to check AC leakage.

MODEL IDENTIFICATION

— BACK PANEL —

Part No.

4-998-603-1 ¹ AEP and UK models 4-998-603-3 ¹ US model

4-998-603-4 ¹ Canadian model

– 4 –